Troubleshooting 8-57
Auto rebuild fails:
Was a sufficient time taken for hot swap of hard disk drives?
To allow the auto rebuild to operate correctly, it should take 60 seconds or longer
for the interval between the removal of the failed hard disk drive and the
installation of a new hard disk drive.
A hard disk drive fails:
Contact your service representative.
Consistency Check cannot be performed:
Is logical disk indicated as "Degraded"?
Replace the failed hard disk drive and execute rebuild process.
Is RAID level of logical disk "RAID0"?
The Consistency Check does not work on RAID0 because it has no data
redundancy.