8-8 Troubleshooting
On-screen error message Recommended action
0B83 BMC IBF or OBF check
failed
1. Take one of the following measures to reboot (reset) the CPU
blade.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
2. Take one of the following measures to power off the CPU
blade and then on.
* Power off the CPU blade from OS, then press the POWER
switch to power on.
* Press the POWER switch to power off the CPU blade, then
press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
3. Power off the CPU blade by issuring an OS command or
press the POWER switch. Take the CPU blade out of the
Blade Enclosure, and install it again. Then, press the POWER
switch to turn on the CPU blade.
4. Replace the CPU blade.
5. If the same error persists, contact your service representative.
0B8A BMC SEL area full 1. Run BIOS SETUP, select [Server] - [Event Log Configuration]
- [Clear All Error Logs] to clear the IPMI system event logs.
2. If the same error persists, contact your service representative.
Note: You can make a backup copy of IPMI system event logs
through the Off-line Maintenance Utility before clearing the
IPMI system event logs on BIOS SETUP.
0B8B BMC progress check
timeout
0B8C BMC command access
failed
0B8D Could not redirect the
console - BMC Busy -
0B8E Could not redirect the
console - BMC Error -
0B8F Could not redirect the
console - BMC Parameter
Error -
1. Take one of the following measures to reboot (reset) the CPU
blade.
* Issue an OS command.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
2. Take one of the following measures to power off the CPU
blade and then on.
* Power off the CPU blade from OS, then press the POWER
switch to power on.
* Press the POWER switch to power off the CPU blade, then
press it again to power on.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
3. Power off the CPU blade by issuring an OS command or
press the POWER switch. Take the CPU blade out of the
Blade Enclosure, and install it again. Then, press the POWER
switch to turn on the CPU blade.
4. Replace the CPU blade.
5. If the same error persists, contact your service representative.
Kommentare zu diesen Handbüchern