8-40 Troubleshooting
Description
On-screen
message
Recommended action
BB +1.5vs Alm00 +1.5VS voltage warning (lower limit) occurred.
BB +3.3vs Alm07 +3.3VS voltage warning (upper limit) occurred.
BB +3.3vs Alm00 +3.3VS voltage warning (lower limit) occurred.
BB +5vs Alm07 +5VS voltage warning (upper limit) occurred.
BB +5vs Alm00 +5VS voltage warning (lower limit) occurred.
BB +12vs Alm07 +12VS voltage warning (upper limit) occurred.
BB +12vs Alm00 +12VS voltage warning (lower limit) occurred.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Power off the CPU blade by issuring an OS command or press the POWER
switch. Take the CPU blade out of the Blade Enclosure, and install it again.
Then, press the POWER switch to turn on the CPU blade.
Replace the CPU blade.
If the same error persists, contact your service representative.
SB +1.2v Alm07 +1.2V voltage warning (upper limit) occurred on SAS unit.
SB +1.2v Alm00 +1.2V voltage warning (lower limit) occurred on SAS unit.
SB +1.35v Alm07 +1.35V voltage warning (upper limit) occurred on SAS unit.
SB +1.35v Alm00 +1.35V voltage warning (lower limit) occurred on SAS unit.
SB +1.5v Alm07 +1.5V voltage warning (upper limit) occurred on SAS unit.
SB +1.5v Alm00 +1.5V voltage warning (lower limit) occurred on SAS unit.
SB +1.8v Alm07 +1.8V voltage warning (upper limit) occurred on SAS unit.
SB +1.8v Alm00 +1.8V voltage warning (lower limit) occurred on SAS unit.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Power off the CPU blade by issuring an OS command or press the POWER
switch. Take the CPU blade out of the Blade Enclosure, and install it again.
Then, press the POWER switch to turn on the CPU blade.
1. Check connection status of signal cable between the CPU unit and the
SAS unit.
2. Check installation status of DIMMs on SAS unit.
Replace the CPU blade.
If the same error persists, contact your service representative.