Troubleshooting 8-19
On-screen error message Recommended action
Invalid System
Configuration Data
System Configuration
Data Read Error
System Configuration
Data Write Error
1. Take one of the following measures to reboot (reset) the CPU
blade.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
2. Replace the CPU blade.
3. If the same error persists, contact your service representative.
WARNING: IRQ not
configured
1. Take one of the following measures to reboot (reset) the CPU
blade.
* Press Ctrl + Alt + Del.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE
Engine or NEC DianaScope Manager.
2. Check installation status of mezzanine card.
3. Replace the mezzanine card.
4. Replace the CPU blade.
5. If the same error persists, contact your service representative.
Other POST Error
The following POST error is not displayed on screen, but recorded in System Event Log.
POST error
code
Meaning Recommended action
02F0
An error is detected while the
processor is being initialized.
Check other POST error message displayed on
screen, and take appropriate action.
Kommentare zu diesen Handbüchern