NEC SigmaBlade B140a-T Betriebsanweisung Seite 125

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 376
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 124
Configuring Your Server 4-73
Manual Rebuild
Described below are procedures based on assumption:
One of the HDDs failed in a RAID5 virtual disk configured with three HDDs.
Replace the failed HDD with new one after turning off the power of the server. Auto Rebuild feature
is disabled for non-hot-swap replacement. Use Manual Rebuild feature to recover the virtual disk as
described below.
1. Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the
right frame of the Top Menu.
In the example below, the hard disk drive in slot number 2 has been replaced.
The indication "PD Missing from DGx: Slot 2: xxxxx MB" represents that the PD
(physical drive) having been installed in slot number 2 was removed.
2. Select "():1:2" (newly connected HDD) in [Physical Drives].
3. The properties for Physical Drive is displayed.
Seitenansicht 124
1 2 ... 120 121 122 123 124 125 126 127 128 129 130 ... 375 376

Kommentare zu diesen Handbüchern

Keine Kommentare