Troubleshooting 8-31
Description
On-screen
message
Recommended action
Proc1Didn'tStart Failed to start CPU #1.
Proc2Didn'tStart Failed to start CPU #2.
Proc3Didn'tStart Failed to start CPU #3.
Proc4Didn'tStart Failed to start CPU #4.
Proc1 Config Err
The CPU installed in the CPU#1 slot is unsupported or its combination is
illegal.
Proc2 Config Err
The CPU installed in the CPU#2 slot is unsupported or its combination is
illegal.
Proc3 Config Err
The CPU installed in the CPU#3 slot is unsupported or its combination is
illegal.
Proc4 Config Err
The CPU installed in the CPU#4 slot is unsupported or its combination is
illegal.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
1. Check installation status of CPU.
2. Replace the CPU.
1. Check installation status of the failed CPU.
2. Check installation status of heat sink on the failed CPU.
3. Replace the failed CPU.
Replace the CPU blade.
If the same error persists, contact your service representative.
WDT Timeout Watchdog timer timeout error occurred.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
If the same error persists, contact your service representative.