8-26 Troubleshooting
Description
On-screen
message
Recommended action
FBD CH1 Unc Err An uncorrectable error occurred on DIMM in DIMM socket 01, 05, 09, or 13.
FBD CH2 Unc Err An uncorrectable error occurred on DIMM in DIMM socket 02, 06, 10, or 14.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
1. Check installation status of DIMMs in DIMM Group#1, 3, 5, or 7.
2. Replace the DIMMs in failed DIMM Group #1, 3, 5, or 7.
Replace the CPU blade.
If the same error persists, contact your service representative.
FBD CH3 Unc Err An uncorrectable error occurred on DIMM in DIMM socket 03, 07, 11, or 15.
FBD CH4 Unc Err An uncorrectable error occurred on DIMM in DIMM socket 04, 08, 12, or 16.
Take one of the following measures to reboot (reset) the CPU blade.
* Press the RESET switch.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
You may continue use or run the system.
1. Check installation status of DIMMs in DIMM Group#2, 4, 6, or 8.
2. Replace the DIMMs in failed DIMM Group #2, 4, 6, or 8.
Replace the CPU blade.
If the same error persists, contact your service representative.