Troubleshooting 8-39
Description
On-screen
message
Recommended action
Proc1 VCCP Alm07 VCCP voltage warning (upper limit) occurred on CPU #1.
Proc1 VCCP Alm00 VCCP voltage warning (lower limit) occurred on CPU #1.
Proc2 VCCP Alm07 VCCP voltage warning (upper limit) occurred on CPU #2.
Proc2 VCCP Alm00 VCCP voltage warning (lower limit) occurred on CPU #2.
Proc3 VCCP Alm07 VCCP voltage warning (upper limit) occurred on CPU #3.
Proc3 VCCP Alm00 VCCP voltage warning (lower limit) occurred on CPU #3.
Proc4 VCCP Alm07 VCCP voltage warning (upper limit) occurred on CPU #4.
Proc4 VCCP Alm00 VCCP voltage warning (lower limit) occurred on CPU #4.
Take one of the following measures to power off then on the CPU blade.
* Power off the CPU blade from OS, then press the POWER switch to
power on.
* Press the POWER switch to power off the CPU blade, then press it
again to power on.
* Issue a command from Web browser of EXPRESSSCOPE Engine or
NEC DianaScope Manager.
Power off the CPU blade by issuring an OS command or press the POWER
switch. Take the CPU blade out of the Blade Enclosure, and install it again.
Then, press the POWER switch to turn on the CPU blade.
1. Check installation status of the failed CPU.
2. Check installation status of heat sink on the failed CPU.
3. Replace the failed CPU.
Replace the CPU blade.
If the same error persists, contact your service representative.
FSB VTT Alm07 FSB VTT voltage warning (upper limit) occurred.
FSB VTT Alm00 FSB VTT voltage warning (lower limit) occurred.
B1 FBD VTT Alm07 DIMM VTT voltage warning (upper limit) occurred.
B1 FBD VTT Alm00 DIMM VTT voltage warning (lower limit) occurred.
B2 FBD VTT Alm07 DIMM VTT voltage warning (upper limit) occurred.
B2 FBD VTT Alm00 DIMM VTT voltage warning (lower limit) occurred.
B1 FBD VCC Alm07 DIMM VCC voltage warning (upper limit) occurred.
B1 FBD VCC Alm00 DIMM VCC voltage warning (lower limit) occurred.
B2 FBD VCC Alm07 DIMM VCC voltage warning (upper limit) occurred.
B2 FBD VCC Alm00 DIMM VCC voltage warning (lower limit) occurred.
B1 FBD VDD Alm07 DIMM VDD voltage warning (upper limit) occurred.
B1 FBD VDD Alm00 DIMM VDD voltage warning (lower limit) occurred.
B2 FBD VDD Alm07 DIMM VDD voltage warning (upper limit) occurred.
B2 FBD VDD Alm00 DIMM VDD voltage warning (lower limit) occurred.
BB +1.5v Alm07 +1.5V voltage warning (upper limit) occurred.
BB +1.5v Alm00 +1.5V voltage warning (lower limit) occurred.
BB +3.3v Alm07 +3.3V voltage warning (upper limit) occurred.
BB +3.3v Alm00 +3.3V voltage warning (lower limit) occurred.
BB +5v Alm07 +5V voltage warning (upper limit) occurred.
BB +5v Alm00 +5V voltage warning (lower limit) occurred.
BB +1.2vs Alm07 +1.2VS voltage warning (upper limit) occurred.
BB +1.2vs Alm00 +1.2VS voltage warning (lower limit) occurred.
BB +1.25vs Alm07 +1.25VS voltage warning (upper limit) occurred.
BB +1.25vs Alm00 +1.25VS voltage warning (lower limit) occurred.
BB +1.5vs Alm07 +1.5VS voltage warning (upper limit) occurred.
Kommentare zu diesen Handbüchern