ND-71548 (E) CHAPTER 4
Page 303
Issue 2
SYSTEM STARTUP
NAP-200-021
Sheet 1/2
Assignment of Office Data
START
Start up the MAT
Enter basic data Assign the following data via the MAT for each of the
office data programming sheet.
“ATIM”: Assignment of Date and Time
“ASYD” (SYS 1, 2, & 3) /ASYDL (SYS 1 & 2):
System Data assignment
“ASYD”: Assign SYS1, INDEX 92, bit 3=1
“AUNT”: Unit Data assignment
“ADTM”: Assign TCP/IP Module data.
Save basic data Save the above data onto the Flash Card using the
“MEM_HDD” Command.
Initialization
(with office Data Loading)
Make sure that the SENSE switch on the CPU Front
Panel has been set to “2”.
Set the keys on the TOPU as follows:
• PROGRAM KEY→NON LOAD
• SYSTEM DATA KEY→LOAD
Press CPURST button on the CPU Front Panel.
Clear the alarm by pressing ALM RST button on the
TOPU.
Assign Office Data Assign data according to the office data programming
sheet.
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required