CHAPTER 3 ND-71548 (E)
Page 238
Issue 2
INSTALLATION PROCEDURE
2. CALCULATION OF THE DISTANCE BETWEEN THE ATI CIRCUIT CARD AND MODULAR ROSETTE
The distance M in Figure 016-3 is determined by the Direct-Current resistance of power supply cables (–48V and
GND). Note that the maximum resistance is 26 Ω as shown in the following formula:
M = a + b + c
≤
26 Ω
M: Maximum Direct–Current resistance between the ATI circuit card and Modular Rosette
a: Direct-Current resistance of power supply cables (–48V and GND) in the range of A
b: Direct-Current resistance of power supply cables (–48V and GND) in the range of B
c: Direct-Current resistance of power supply cables (–48V and GND) in the range of C
Example of Calculation
a, b, and c are calculated by the following formula:
Note: You are not required to use cable lengths in meters in the following formula. You may use cable lengths in
feet, yards, or whatever unit you prefer. However, the units of resistance you use must match the units of
length you use. For example, if you use distance in feet, you must also use DC resistance per foot.
u: Direct-Current resistance per meter in the range of A (
Ω/m)
v: Direct-Current resistance per meter in the range of B (
Ω/m)
w: Direct-Current resistance per meter in the range of C (
Ω/m)
x: Cable length (m) in the range of A
y: Cable length (m) in the range of B
z: Cable length (m) in the range of C
NAP-200-016
Sheet 6/44
Installation of the DESK CONSOLE and
Cable Connection
c =
w (Ω/m)
× z (m)
2
+
w (Ω/m)
× z (m)
2
Resistance of –48V cables
Resistance of GND cables
Number of –48V cables
Number of GND cables
a =
u (Ω/m)
× x (m)
2
+
u (Ω/m)
× x (m)
1
Resistance of –48V cables
Resistance of GND cables
Number of –48V cables
Number of GND cable
b =
v (Ω/m)
× y (m)
2
+
v (Ω/m)
× y (m)
2
Resistance of –48V cables
Resistance of GND cables
Number of –48V cables
Number of GND cables