Removing and Replacing a CPU-I/O Enclosure
CRU Replacement Procedures 5-5
Removing a CPU-I/O Enclosure
WARNING
!
To avoid personal injury or damage to the system, two
persons are required to replace an enclosure.
1. If necessary, use ftServer Management Console (ftSMC) to take the enclosure
offline. See the Help for ftSMC for detailed instructions.
Verify that the enclosure is offline before proceeding.
2. Remove the bezel, as described in “Removing and Replacing the Bezel” on
page 5-3.
3. Disconnect all of the data cables from the rear of the enclosure. Then, disconnect
the power cord.
CAUTION
!
You must disconnect the VTM network cable before you
disconnect the power cord. When you remove the power
cord, the mechanical interlock at the rear of the system
springs into the unlocked position and could damage the
VTM connector or cable (Figure 5-2, inset).
4. Ensure that the mechanical interlock on the rear of the enclosure is in the unlocked
position (number 1 in Figure 5-2). If the system is in a rack, the unlocked position
is the vertical position. If the system is in a pedestal case, the unlocked position is
the horizontal position.