83
Setting Rebuild Priority
You can set the priority at which Rebuild is executed in the computer. The procedure of setting the Rebuild
Priority is described below.
Setting Rebuild Priority are available only in the Advanced Mode.
RAID Viewer
Change the property of RAID Controller.
Step 1
Start the RAID Viewer. Click the RAID Controller on the Tree View. Then click [Properties] on the pull-down
menu of menu item [File].
Step 2 Click the [Options] tab in the [RAID
Controller Properties] dialog box. Change the value of
[Rebuild Priority] to [High], [Middle], or [Low]. Click
[OK] or [Apply].
raidcmd
Use "optctrl" command.
Step 1 Execute "optctrl" command with -rp option
and the defined parameters.
-c : Number of the RAID Controller for which Rebuild
Priority is set
-rp : Value set after Rebuild Priority is set(Select a value
out of High, Middle, and Low)
Step 2 Check the execution result by using
"
property" command.
> raidcmd optctrl -c=1 -rp=Middle
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Corporation
Model : MegaRAID SAS PCI Express(TM)
ROMB
Firmware Version : 1.12.02-0342
Cache Size : 128MB
Battery Status : Normal
Rebuild Priority : Middle
Consistency Check Priority : Low
Patrol Read : Enable
Patrol Read Priority : Low
Buzzer Setting : Enable
>