NEC Express5800/R110d-1E Betriebsanweisung Seite 81

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 106
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 80
81
Rebuilding Physical Device
Rebuild means incorporation of a new Physical Device to a Logical Drive after a Physical Device is replaced with the new
one due to occurrence of an event such as a failure. In general, the Rebuild is automatically started by a function of the
RAID Controller called standby rebuild or hot-swap rebuild. Accordingly, manual Rebuild is not required so often. If
required, use the Universal RAID Utility.
Manual Rebuild is available only in the Advanced Mode.
Executing Rebuild
Rebuild is executed for a Physical Device. The procedure of executing Rebuild is described below.
Rebuild can be executed if [Status] of a Physical Device is set to [Failed] and [Status] of the
Logical Drive using the Physical Device is set to [Degraded].
RAID Viewer
Use [Rebuild] in [Control] menu.
Step 1
Connect the Physical Device used for Rebuild to a RAID Controller at this timing if required. If the Physical
Device is connected completely, start the RAID Viewer.
Step 2 Click the Physical Device used for the Rebuild on the Tree View. Then
click [Rebuild] on the pull-down menu of menu item [Control].
Step 3 After the Rebuild is started, the progress
of the Rebuild appears on the Operation View.
At the completion of the Rebuild, [Status] on the
Operation View is changed to [Completed].
raidcmd
Use "rebuild" command.
Step 1
Connect the Physical Device used for Rebuild to a RAID Controller at this timing if required.
Step 2 Execute "rebuild" command with -op
option and the defined parameters.
-c : Number of the RAID Controller containing the
Physical Device for which Rebuild is executed
-p : Number of the Physical Device for which Rebuild
is executed
-op : Specify "start" to start Rebuild
> raidcmd rebuild -c=1 -p=3 -op=start
>
> raidcmd oplist
RAID Controller #1
PD #3 : Rebuild (Running 70%)
>
2
3
Seitenansicht 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 105 106

Kommentare zu diesen Handbüchern

Keine Kommentare