NEC Express5800/R120d-2E SR Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach RAID-Kontroller NEC Express5800/R120d-2E SR herunter. NEC Express5800/R120d-2E SR User's Guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Appendix C : Logs/Events
The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log.
[Event Source, Alert Type]
Source Name of Event Log (only Windows) : raidsrv
Alert Type : URAIDUTL
[Log]
Mark
Description
R Universal RAID Utility logs this event to RAID Log.
O Universal RAID Utility logs this event to OS log.
[Alert]
Mark Description
M and MA Universal RAID Utility send this event to NEC ESMPRO Manager as alert.
The [ Address ] description is different from the category of event.
[
Address
] description in [Description]
Category of Event Type Description
RAID Controller
Battery
1 [CTRL:%1(ID=%2)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
Physical Device 2 [CTRL:%1(ID=%2) PD:%3(ID=%4) %5%6]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Physical Device
%4 : ID of Physical Device
%5 : Vendor and Model of Physical Device
%6 : Firmware Version of Physical Device
Logical Drive 3 [CTRL:%1(ID=%2) LD:%3(ID=%4)]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
Enclosure 4 [CTRL:%1(ID=%2) ENC:%3]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
Power Supply Unit in Enclosure 5 [CTRL:%1(ID=%2) ENC:%3 POW:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Power Supply Unit
Fan Unit in Enclosure 6 [CTRL:%1(ID=%2) ENC:%3 FAN:%4]
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Enclosure
%4 : Number of Fan Unit
Seitenansicht 0
1 2 3 4 5 6 7 8 9

Inhaltsverzeichnis

Seite 1 - Appendix C : Logs/Events

1 Appendix C : Logs/Events The list of log and event , alert messages that Universal RAID Utility logs to RAID Log and OS Log. [Event Source, Ale

Seite 2 - [priority, facility]

2 The messages of Universal RAID Utility have the following priority and facility on Linux or VMware ESX. [priority, facility] kind priority faci

Seite 3

3 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0201 (400000C9) Information [Address Type 1 ] The buzzer of RAID Cont

Seite 4

4 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0219 (400000DB) Information [Address Type 1 ] RAID Controller propert

Seite 5

5 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0320 (C0000140) Fatal [Address Type 2 ] Medium Error was detected in

Seite 6

6 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0410 (4000019A) Information [Address Type 3 ] Consistency Check compl

Seite 7

7 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0424 (800001A8) Warning [Address Type 3 ] A Warning Error happened to

Seite 8

8 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0506 (800001FA) Warning [Address Type 1 ] The voltage of Battery is l

Seite 9

9 Event ID (hex digit) Severity Description Log Alert Summary Deal Method 0702 (400002BE) Information raidsrv Configuration [CTRL:%1(ID=%2)] V

Kommentare zu diesen Handbüchern

Keine Kommentare