115
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method Memo
0413
(C000019D)
Fatal [Address Type 3 ] Data Inconsistency was
detected in Logical Drive by Consistency Check
and corrected.
RO MA Data Inconsistency
Error Corrected
Please execute Consistency Check again when
the load of the system is low. If the error does
not occur on the second time of Consistency
Check, the Physical Device does not have any
problems. If the same error occurs, please
replace the Physical Device for the preventive
maintenance (please be sure to ask NEC
customer service before the replacement to
identify which Physical Device has a failure).
After replacing the Physical Device, restore the
backup data to the Logical Drive.
0415
(4000019F)
Information
[Address Type 3 ] Logical Drive was created. R
0416
(400001A0)
Information
[Address Type 3 ] Logical Drive was deleted. R
0417
(400001A1)
Information
[Address Type 3 ] The Cache Mode of Logical
Drive was changed. (Value : %1)
hangedRO M Cache Mode C
None %1 : Changed value
*1
0418
(40 2) 0001A
Information
[Address Type 3 ] Background Initialization
was started.
R
(400001A3)
Information0419
[Address Type 3 ] Background Initialization
completed.
R
0420
(800001A4)
Warning [Address Type 3 ] Background Initialization
failed.
RO MA Background
Initialization Failed
The RAID System may have some kind of
problem. Please deal with the problem of the
RAID System.
0421
(40 5)
Information
0001A
[Address Type 3 ] Background Initialization R
was stopped.
0422
(C00001A6)
Fatal [Address Type 3 ] An error was detected in
Logical Drive but could not correct.
RO MA Logical Drive
Uncorrectable Error
Please replace the Physical Device (You need
to ask it which Physical Device do you
replace). After replacement of Physical Device,
recreate the Logical Drive and restore the
backup data to it.
0423
(400001A7)
Information
[Address Type 3 ] An error was detected in
Logical Drive and corrected.
ogical Drive
Corrected Error
lease replace the Physical Device for the
prevention of failure(You need to ask it which
hysical Device do you replace). Next restore
the backup data to the Logical Drive after
RO MA L P
P
replacement of Physical Device.
0424
(800001A8)
Warning [Address Type 3 ] A Warning Error happened to
Logical Drive. Detail : %1
RO M Logical Drive Warning
The RAID Controller and/or the Physical
Device may have some kind of problem. You
need to ask it which component has broken.
%1 : Detail