106
Valid period of mode after change
The running mode is valid unless it is changed by runmode command. The running mode remains
unchanged if the computer is rebooted.
sbuzzer
[Overview]
Stops the Buzzer on a RAID Controller.
[Format]
raidcmd sbuzzer -c=<controller>
Command Parameter Description
-c=<controller> Specify the RAID Controller to be processed.
<controller> : RAID Controller Number
[Description]
ding in the specif
erminates normally if it Buzzer sounding.
sl
Stops the Buzzer soun
The command t
ied RAID Controller.
is executed without
otlamp
[Ov
[Format]
raidcmd slotlamp -c=<controller> -p=<physicaldevice> -sw={on|off}
erview]
Turns on or off the DISK lamp of the computer or enclosure in which Physical Devices are installed.
Command Parameter Description
-c=<controller> Specify the RAID Controller to be processed.
<controller> : RAID Controller Number
-p=<physicaldevice> Specify the Physical Device to be processed.
<physicaldevice> : Physical Device Number
-sw={on|off}
Specify that the lamp is turned on or off.
on: Turns on the lamp.
off: Turns off the lamp.
[Description]
Turns on or off the DISK lamp on the computer or enclosure in which the specified Physical Device is installed.
Executing the raidcmd with -sw=on while the DISK lamp is already ON causes the command to terminate
normally.
Executing the raidcmd with -sw=off while the DISK lamp is already OFF causes the command to terminate
stspd
normally.
[Overview]
l Device to online or failed forcibly.
[Format]
-p=<phys
Changes the status of a Physica
raidcmd
stspd -c=<controller> icaldevice> -st={online|offline} [-y]
Command Parameter Description
-c=<controller> ntroller to be processed.
oller Number
Specify the RAID Co
<controller> : RAID Contr
-p=<physicaldevice> Specify the Physical Device to be processed.
<physicaldevice> : Physical Device Number
-st={online|offline}
Specify the altered status.
online: Online status
offline: Failed status
Kommentare zu diesen Handbüchern