8-18 Troubleshooting
Messages displayed by RAID Controller during POST
On-screen message Action
Memory/battery problems were detected.
The adapter has recovered, but cached
data was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Firmware version inconsistency was
detected.
The adapter has recovered, but cached
data was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the
configuration utility.
Press C to run the utility to import or clear
configuration.
Previous configuration cleared or missing
Importing configuration created on
MM/DD hh:mm
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
An enclosure was found that contains both
SAS and SATA drives, but this controller
does not allow mixed drive types in a single
enclosure. Please correct the problem then
restart your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SAS drives were detected, but this
controller does not support SAS drives.
Please remove the SAS drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SATA drives were detected, but this
controller does not support SATA drives.
Please remove the SATA drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
Invalid SAS topology detected. Please
check your cable configurations, repair the
problem, and restart your system.
Check if cable is connected properly. If the same
error persists, contact your service representative.
The battery hardware is missing or
malfunctioning, or the battery is unplugged.
If you continue to boot the system, the
battery-backed cache will not function.
Please contact technical support for
assistance.
Press 'D' to disable this warning (if your
controller does not have a battery).
<When battery is not used>
Press D to hide this message.
<When battery is used>
Check if battery is connected properly. If the same
error persists, contact your service representative.