8-22 Troubleshooting
Beep Codes
If an error occurs during the POST, the server beeps, indicating the type of error.
Each number indicates the number of short beeps, and a hyphen indicates a pause. For example, the
beep interval 1-3-3-1 indicates 1 beep, a pause, 3 beeps, a pause, 3 beeps, a pause, and 1 beep,
which indicates that an error occurred while checking the memory capacity.
Beep code Description Recommended action
1-3-3-1 No memory could be detected.
An error occurred during a
memory capacity check.
Make sure that the DIMMs are correctly inserted.
If this does not resolve the problem, contact your
service representative and request either DIMM
or motherboard replacement.
1-1
No graphics controller could be
detected.
Contact your service representative and request
motherboard replacement.
1
An error was detected during the
POST processing or
DIMM has already been
installed.
3
Failed to read the BIOS
executable module. Or, BIOS
has no executable module.
4
Failed to initialize the BIOS
executable module.
7 Failed to reset the system.
Contact your service representative and request
motherboard replacement.