NEC Express5800/R110f-1E Einstellungsanleitung

Stöbern Sie online oder laden Sie Einstellungsanleitung nach Gateways / Controller NEC Express5800/R110f-1E herunter. NEC Express5800/R110f-1E Setup Guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 125
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Setup Guide
Front Cover
Chapter 1 Setup for Managed Component
integrated EXPRESSSCOPE Engine 3
Chapter 2 Setup for Managed Component
integrated BMC excluding EXPRESSSCOPE
Engine 3 (for LAN connection)
Chapter 3 Setup for the Managed Component
integrated BMC excluding EXPRESSSCOPE
Engine 3 (for modem / direct connection)
Chapter 4 EM Card and Chassis Management
Chapter 5 Setup for the NEC Storage M series
Chapter 6 Setup for the Managed Component
based on vPro
Chapter 7 Setup for the VMware ESXi5 server
Chapter 8 Removing components and groups
Appendix A
Appendix B
Appendix C
Appendix D
NEC ESMPRO Manager Ver.6
Express5800 Series
Ver.1.00
©NEC Corporation 2014
Seitenansicht 0
1 2 3 4 5 6 ... 124 125

Inhaltsverzeichnis

Seite 1 - NEC ESMPRO Manager Ver.6

Setup Guide Front Cover Chapter 1 Setup for Managed Component integrated EXPRESSSCOPE Engine 3

Seite 2 - Contents

NEC ESMPRO Manager Setup Guide 9 1.2.1 Configuration with EXPRESSSCOPE Engine 3 WebConsole Explain the operation of Web Console of EXPRESSSCOPE En

Seite 3

NEC ESMPRO Manager Setup Guide 99 CHECK: ・*2 On “Environment” – “Auto Registration Setting List” screen, you can manage a list of username/password

Seite 4 - Terminology

NEC ESMPRO Manager Setup Guide 100 Chapter8 Removing components and groups 8.1 Removing components (1)Select a group which target components be

Seite 5

NEC ESMPRO Manager Setup Guide 101 (3)Click “Delete” button and you can remove checked components from NEC ESMPRO Manager. 8.2 Removing group

Seite 6 - About This Document

NEC ESMPRO Manager Setup Guide 102 (2)Check target groupss. (3)Click “Delete” button and you can remove checked groups from NEC ESMPRO Manager. A

Seite 7

NEC ESMPRO Manager Setup Guide 103 Appendix A. How to setup for the managed component that does not has local console Even if a managed component d

Seite 8 - 1.1 Setup Flow

NEC ESMPRO Manager Setup Guide 104 2. Configure BMC on a managed component. (1) Configure BMC of the managed component. When you use LAN connecti

Seite 9

NEC ESMPRO Manager Setup Guide 105Appendix B. How to setup for using NEC ESMPRO Agent Extension or NEC DianaScope Agent on the managed component tha

Seite 10

NEC ESMPRO Manager Setup Guide 106 2. Set BMC configuration by using the NEC DianaScope Agent. (1) See 2.2.1”Configuration with NEC ESMPRO Agent Ex

Seite 11

NEC ESMPRO Manager Setup Guide 107 B.2 On the managed component that BMC uses Management LAN port Please setup the NEC ESMPRO Manager with the proc

Seite 12

NEC ESMPRO Manager Setup Guide 108 Appendix C. Port number for WS-Man communication A port number where WS-Man service listens for connection is as

Seite 13

NEC ESMPRO Manager Setup Guide 10 "Configuration" screen will be displayed. Select "Miscellaneous". "Miscellaneous"

Seite 14 - 1.2.2 Online Configuration

NEC ESMPRO Manager Setup Guide 109 Appendix D. Managed Components Summary The NEC ESMPRO Manager has following functions for BMC conforming to mana

Seite 15

NEC ESMPRO Manager Setup Guide 110Remote Console: “Supported” means that the managed component supports the Remote Console function. Scheduled Runn

Seite 16

NEC ESMPRO Manager Setup Guide 111Express5800/100 series (Tower/Rack Server) Product name BMC Standard LAN2 Management LAN PortRemote Console Schedu

Seite 17

NEC ESMPRO Manager Setup Guide 112 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 18

NEC ESMPRO Manager Setup Guide 113 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 19

NEC ESMPRO Manager Setup Guide 114 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 20

NEC ESMPRO Manager Setup Guide 115 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 21

NEC ESMPRO Manager Setup Guide 116 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 22

NEC ESMPRO Manager Setup Guide 117Express5800/Blade Server Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower o

Seite 23 - 1.3.1 Environment setting

NEC ESMPRO Manager Setup Guide 118 Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower option setting SOL Electr

Seite 24

NEC ESMPRO Manager Setup Guide 11 CHECK: ・If a managed component supports SOL and "Redirection" is selected to "Enable", you mu

Seite 25

NEC ESMPRO Manager Setup Guide 119 Express5800/iModel (Data Center Server) Product name BMC Standard LAN2 Management LAN PortRemote Console Schedule

Seite 26 - 1.3.3.1 Manual Registration

NEC ESMPRO Manager Setup Guide 120 Fault tolerant server Product name BMC Standard LAN2 Management LAN PortRemote Console Scheduled runningPower opt

Seite 27

NEC ESMPRO Manager Setup Guide 121 Express5800/The highly parallel computing server Product name BMC Standard LAN2 Management LAN PortRemote Console

Seite 28

NEC ESMPRO Manager Setup Guide 122 <Notes for Each Managed Component> This section explains the functional difference and notes of each manage

Seite 29

NEC ESMPRO Manager Setup Guide 1232-(l) NEC ESMPRO Manager cannot display the blade enclosure (chassis) information for this product. The product do

Seite 30

NEC ESMPRO Manager Setup Guide 124 Revision History 1.00 2014/08/01 (Ver6.00) Initial release for Ver.6

Seite 31

NEC ESMPRO Manager Setup Guide 12 CHECK: ・Please set the following items for NEC ESMPRO Manager to receive alerts from the BMC. - Miscellaneous

Seite 32

NEC ESMPRO Manager Setup Guide 13 1.2.2 Online Configuration 1.2.2.1 Configuration with Configuration tool for Windows Explain the operation of C

Seite 33 - 1.3.3.2 Auto Registration

NEC ESMPRO Manager Setup Guide 14 Select Network configuration screen. ・In the case of BMC Configuration: “Set BMC Configuration”  “Network” ・In th

Seite 34

NEC ESMPRO Manager Setup Guide 15 CHECK: ・Please set the following items for NEC ESMPRO Manager to receive alerts from the BMC. - Miscellaneous

Seite 35

NEC ESMPRO Manager Setup Guide 16 1.2.2.2 Configuration with Configuration tool for Linux Explains the operation of Configuration tool for Linux.

Seite 36

NEC ESMPRO Manager Setup Guide 17 Select network configuration screen. ・In the case of BMC Configuration: “Set BMC Configuration”  “BMC Configurati

Seite 37

NEC ESMPRO Manager Setup Guide 18 CHECK: ・Please set the following items for NEC ESMPRO Manager to receive alerts from the BMC. - Miscellaneous

Seite 38

1 Contents Front Cover ...

Seite 39 - (for LAN connection)

NEC ESMPRO Manager Setup Guide 19 1.2.3 Configuration with Off-line BMC Configuration The following message is displayed on the bottom of POST sc

Seite 40

NEC ESMPRO Manager Setup Guide 20CHECK: ・If a managed component supports SOL and "Redirection" is selected to "Enable", you must

Seite 41

NEC ESMPRO Manager Setup Guide 21 If you set "Default Gateway", confirm that the gateway is connected to network. Select "OK".

Seite 42

NEC ESMPRO Manager Setup Guide 22 1.3 Register a managed component on NEC ESMPRO Manager To register the managed component on the NEC ESMPRO Man

Seite 43

NEC ESMPRO Manager Setup Guide 23Information" tab. Enter the group name, and click "Add". The following screen shows an example.

Seite 44

NEC ESMPRO Manager Setup Guide 24

Seite 45

NEC ESMPRO Manager Setup Guide 25 1.3.3 Register the Managed Component Use either of the two methods to register the managed component. Manual Reg

Seite 46

NEC ESMPRO Manager Setup Guide 26 Click the "Manual Registration" from "Add Component" of "Group Information" tab. I

Seite 47

NEC ESMPRO Manager Setup Guide 27SNMP Community Name(Get) SNMP Community Name which is specified at SNMP Agent running on the managed component. It

Seite 48

NEC ESMPRO Manager Setup Guide 28If the managed component is a server which has EXPRESSSCOPE Engine SP3(2BMC model), you should enter the IP address

Seite 49

2 5.1.1 Manual Registration ... 86 5.1.2

Seite 50

NEC ESMPRO Manager Setup Guide 29 The following screen shows an example. Click "Add". TIPS: ・A managed component cannot be controlled r

Seite 51

NEC ESMPRO Manager Setup Guide 30 Click "Connection Setting" from "Setting" tab of the managed component. "Connection Setti

Seite 52

NEC ESMPRO Manager Setup Guide 31 Click "Check Connection" and following screen will be displayed. After finishing connection check, “C

Seite 53

NEC ESMPRO Manager Setup Guide 32 1.3.3.2 Auto Registration Click the managed component's "Group name" on the "Group" t

Seite 54

NEC ESMPRO Manager Setup Guide 33Input the following items: Name Value Destination Group Specify the group to which the managed component will be

Seite 55

NEC ESMPRO Manager Setup Guide 34CHECK: ・*3 On “Environment” – “Auto Registration Setting List” screen, you can manage a list of username/password a

Seite 56

NEC ESMPRO Manager Setup Guide 35 When the "Auto Registration" is completed, the NEC ESMPRO Manager starts to control the managed componen

Seite 57 - LAN connection)

NEC ESMPRO Manager Setup Guide 36 1.3.3.3 Auto Registration Setting Before executing auto registration, User Name/Password and Authentication Key c

Seite 58

NEC ESMPRO Manager Setup Guide 37 (3)Enter each item. WS-Man - “User Name/Password” Enter a pair of username and password for WS-Man auto re

Seite 59

NEC ESMPRO Manager Setup Guide 38 Chapter2 Setup for Managed Component in which a BMC excluding EXPRESSSCOPE Engine 3 is integrated (for LAN conn

Seite 60

NEC ESMPRO Manager Setup Guide 3 Terminology Term Description BMC Baseboard Management Controller An Embedded controller which is able to monito

Seite 61

NEC ESMPRO Manager Setup Guide 39 2.2 Configure BMC on Managed Component (for LAN connection) Configure BMC of the managed component at first. TIP

Seite 62

NEC ESMPRO Manager Setup Guide 40

Seite 63

NEC ESMPRO Manager Setup Guide 41 "BMC Configuration" dialog box will be display. Click "Common" tab page. Be sure to set the be

Seite 64

NEC ESMPRO Manager Setup Guide 42 Select "LAN1" tab page for LAN port 1 of the BMC. Set the below items. The other items can be used with

Seite 65 - 2.3.2.1 Manual Registration

NEC ESMPRO Manager Setup Guide 43 The following screen shows example. TIPS: ・The "LAN2" tab is displayed only w

Seite 66

NEC ESMPRO Manager Setup Guide 44 If you set "Default Gateway", please connect the managed component via LAN port used by BMC and the gate

Seite 67

NEC ESMPRO Manager Setup Guide 45 2.2.1.2 Configuration with NEC ESMPRO Agent Extension ver.1.xx for Linux This section explains the configuration

Seite 68

NEC ESMPRO Manager Setup Guide 46"Set System Management Parameters" screen will be displayed. Select "Configuration".

Seite 69

NEC ESMPRO Manager Setup Guide 47 "BMC Configuration" screen will be displayed. Select "Common". "Comm

Seite 70

NEC ESMPRO Manager Setup Guide 48 TIPS: ・If a managed server is compatible with SOL and "Enable" is selected for the item "Redirec

Seite 71

NEC ESMPRO Manager Setup Guide 4 Trademarks EXPRESSBUILDER, NEC ESMPRO and EXPRESSSCOPE are registered trademarks of NEC Corporation. Microsoft, Wi

Seite 72 - 2.3.2.2 Auto Registration

NEC ESMPRO Manager Setup Guide 49-- "Default Gateway" Enter the default gateway if the managed server connects to NEC ESMPRO Manager S

Seite 73

NEC ESMPRO Manager Setup Guide 50CHECK: ・The "LAN2" in "BMC Configuration" screen is displayed only when the managed component&a

Seite 74

NEC ESMPRO Manager Setup Guide 51 2.2.2 Configuration with NEC EXPRESSBUILDER DOS based with remote console feature (for LAN connection) NEC EXPRES

Seite 75

NEC ESMPRO Manager Setup Guide 52 The "BMC Configuration" dialog box will appear. Click "Common" tab page. Be sure to set the be

Seite 76

NEC ESMPRO Manager Setup Guide 53 Select "LAN" tab page for LAN port 1 of the BMC. Set the below items. The other items can be used with t

Seite 77

NEC ESMPRO Manager Setup Guide 54supports the function of "Obtain an IP Address automatically (DHCP)". CHECK: ・Please set the following i

Seite 78

NEC ESMPRO Manager Setup Guide 55 2.2.2.2 Run NEC EXPRESSBUILDER DOS based with remote console feature If you set "Default Gateway" at cr

Seite 79

NEC ESMPRO Manager Setup Guide 562.2.3 Configuration with NEC EXPRESSBUILDER System Management (for LAN connection) This section explains the con

Seite 80

NEC ESMPRO Manager Setup Guide 57Set System Management Parameters" screen will be displayed. Select "Configuration".

Seite 81

NEC ESMPRO Manager Setup Guide 58"BMC Configuration" screen will be displayed. Select "Common". "Commo

Seite 82 - 4.2 System Requirements

NEC ESMPRO Manager Setup Guide 5 About This Document This document introduces remote management using the server management utility "NEC ESMPR

Seite 83 - 4.3 Setup for EM Card

NEC ESMPRO Manager Setup Guide 59 TIPS: ・If a managed server is compatible with SOL and "Enable" is selected for the item "Redirecti

Seite 84 - 4.3.4 Manual Registration

NEC ESMPRO Manager Setup Guide 60The following screen shows example. -- "Alert Receiver / Management PC(1)". Enter t

Seite 85 - 4.3.5 Auto Registration

NEC ESMPRO Manager Setup Guide 61 CHECK: ・Please set the following items for NEC ESMPRO Manager to receive alerts from the BMC. - LAN1 (Alert) / LAN

Seite 86 - 4.4 Operation of EM card

NEC ESMPRO Manager Setup Guide 62 2.3 Register a managed component on NEC ESMPRO Manager (for LAN connection) To register the managed component on

Seite 87 - 5.1.1 Manual Registration

NEC ESMPRO Manager Setup Guide 63 Enter the group name, and click "Add". The following screen shows an example. The added group will b

Seite 88 - 5.1.2 Auto Registration

NEC ESMPRO Manager Setup Guide 64 2.3.2 Register the Managed Component (for LAN connection) Use either of the two methods to register the managed c

Seite 89

NEC ESMPRO Manager Setup Guide 65 Click the "Manual Registration" from "Add Component" of "Group Information" tab.

Seite 90 - Manager

NEC ESMPRO Manager Setup Guide 66SNMP Community Name(Get) SNMP Community Name which is specified at SNMP Agent running on the managed component. It

Seite 91 - 6.3.3 Manual Registration

NEC ESMPRO Manager Setup Guide 67If the managed component is a server which has EXPRESSSCOPE Engine SP3(2BMC model), you should enter the IP address

Seite 92

NEC ESMPRO Manager Setup Guide 68 Click "Add". TIPS: ・A managed component cannot be controlled remotely by only registering it. Perform

Seite 93 - 6.3.4 Auto Registration

NEC ESMPRO Manager Setup Guide 6 About the advanced software and the user support See the following URL for NEC ESMPRO Manager information. You can

Seite 94

NEC ESMPRO Manager Setup Guide 69 Click "Check Connection" and following screen will be displayed.

Seite 95 - 7.1 Setup Flow

NEC ESMPRO Manager Setup Guide 70 After finishing connection check, “Check Connection Execution Result” screen is shown. Detected Detail Detected

Seite 96

NEC ESMPRO Manager Setup Guide 71 2.3.2.2 Auto Registration Click the managed component's "Group name" on the "Group" tree

Seite 97 - 7.3.4 Manual Registration

NEC ESMPRO Manager Setup Guide 72 Input the following items: Name Value Destination Group Specify the group to which the managed component will

Seite 98

NEC ESMPRO Manager Setup Guide 73・*2 On “Environment” – “Auto Registration Setting List” screen, you can manage a list of username/password and auth

Seite 99 - 7.3.5 Auto Registration

NEC ESMPRO Manager Setup Guide 74 When the "Auto Registration" is completed, the NEC ESMPRO Manager starts to control the managed componen

Seite 100

NEC ESMPRO Manager Setup Guide 75 Chapter3 Setup for the Managed Component in which a BMC excluding EXPRESSSCOPE Engine 3 is integrated (for mod

Seite 101 - 8.1 Removing components

NEC ESMPRO Manager Setup Guide 76 3.2 Configure BMC on Managed Component (for modem/direct connection) Configure BMC of the managed component at fi

Seite 102 - 8.2 Removing groups

NEC ESMPRO Manager Setup Guide 77 3.2.1 Configuration with NEC ESMPRO Agent Extension (for modem/direct connection) This section explains the confi

Seite 103

NEC ESMPRO Manager Setup Guide 78 3.2.2 Configuration with NEC EXPRESSBUILDER DOS based with remote console feature (for modem/direct connection) N

Seite 104

NEC ESMPRO Manager Setup Guide 7 Chapter1 Setup for Managed Component in which EXPRESSSCOPE Engine 3 is integrated This chapter explains the setup

Seite 105

NEC ESMPRO Manager Setup Guide 79 CHECK: ・Place the configuration information FD in the write-enable state 3.2.2.2 Run NEC EXPRESSBUILDER DOS bas

Seite 106

NEC ESMPRO Manager Setup Guide 80Click "Manual Registration" of "Add Component" on the "Group Information" tab. Inpu

Seite 107

NEC ESMPRO Manager Setup Guide 81 Chapter4 EM Card and Chassis Management 4.1 Overview The NEC ESMPRO Manager has following functions by communi

Seite 108

NEC ESMPRO Manager Setup Guide 82 4.3 Setup for EM Card 4.3.1 Setup Flow Perform the following setup procedure: Connect the NEC ESMPRO Manager s

Seite 109

NEC ESMPRO Manager Setup Guide 83 4.3.4 Manual Registration (1) Click the group name for the EM card on the "Component Link" view or &

Seite 110

NEC ESMPRO Manager Setup Guide 84subnet mask of the management LAN port for the CPU/IO module 0 to the form. If the managed component is a server wh

Seite 111

NEC ESMPRO Manager Setup Guide 85Discovery Select “Disable” RAID system management Management Select “Disable” NEC ExpressUpdate Updates via NEC Exp

Seite 112

NEC ESMPRO Manager Setup Guide 86 Chapter5 Setup for the NEC Storage M Series 5.1 Register NEC Storage on NEC ESMPRO Manager You can register th

Seite 113

NEC ESMPRO Manager Setup Guide 87Management Controller BMC (EXPRESSSCOPE Engine)/ vPro (Common) Management Select "Unregistration". (4)Cl

Seite 114

NEC ESMPRO Manager Setup Guide 88ExpressUpdate Agent BMC (EXPRESSSCOPE Engine) Discovery Select "Disable". Intel(R) vPro(TM) Technology Di

Seite 115

NEC ESMPRO Manager Setup Guide 8 1.2 Configure BMC on Managed Component Configure BMC of the managed component at first. TIPS: ・This section expla

Seite 116

NEC ESMPRO Manager Setup Guide 89 Chapter6 Setup for the Managed Component based on vPro 6.1 Setup Flow Setup by the following setup procedures:

Seite 117

NEC ESMPRO Manager Setup Guide 90 6.3.2 Register the Managed Component Use either of following two methods to register the managed component. Manu

Seite 118 - Express5800/Blade Server

NEC ESMPRO Manager Setup Guide 91Protocol Port Number Enter port number where WS-Man service listens for connection. *3 RAID system management Mana

Seite 119

NEC ESMPRO Manager Setup Guide 92CHECK: ・This IP Address and OS IP Address are the same if you set the DHCP mode to "ENABLED" on the iAMT

Seite 120

NEC ESMPRO Manager Setup Guide 93 CHECK: ・*1 If NEC ESMPRO Manager is installed on Linux system, “SNMP” is not supported. CHECK: ・*2 If a self-sign

Seite 121

NEC ESMPRO Manager Setup Guide 94 Chapter7 Setup for the VMware ESXi5 server 7.1 Setup Flow Setup by the following setup procedures: Connect th

Seite 122

NEC ESMPRO Manager Setup Guide 95 7.3.2 Add Group which the managed component will belong See “1.3.2 Add Group to which the managed component wil

Seite 123

NEC ESMPRO Manager Setup Guide 96 7.3.4 Manual Registration (1) Click the group name to which the VMware ESXi5 server will belong. (2) Click the

Seite 124 - Component based on vPro

NEC ESMPRO Manager Setup Guide 97management LAN port for the Master BMC to the form. Subnet Mask1 Enter the subnet mask that is specified on LAN1 o

Seite 125 - 1.00 2014/08/01 (Ver6.00)

NEC ESMPRO Manager Setup Guide 98Check parameters corresponding to the feature. 7.3.5 Auto Registration (1) Click the group name to which the V

Kommentare zu diesen Handbüchern

Keine Kommentare