NEC ESMPRO Manager Setup Guide
97
management LAN port for the Master BMC to the form.
Subnet Mask1 Enter the subnet mask that is specified on LAN1 of the BMC
configuration for the managed component.
If the managed component is a fault tolerant server, you should enter the
subnet mask of the management LAN port for the CPU/IO module 0 to
the form.
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the subnet mask of the
management LAN port for the Master BMC to the form.
IP Address 2 Enter the IP address that is specified on LAN2 of the BMC configuration
for the managed component.
If the managed component is a fault tolerant server, you should enter the
IP address of the management LAN port for the CPU/IO module 1 to the
form.
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the IP address of the
management LAN port for the Standby BMC to the form.
Subnet Mask1 Enter the subnet mask that is specified on LAN2 of the BMC
configuration for the managed component.
If the managed component is a fault tolerant server, you should enter the
subnet mask of the management LAN port for the CPU/IO module 1 to
the form.
If the managed component is a server which has EXPRESSSCOPE
Engine SP3(2BMC model), you should enter the subnet mask of the
management LAN port for the Standby BMC to the form.
CHECK:
・*1 If a self-signed certificate is installed on the managed server for HTTPS
communication, a setting to allow it is required. Refer to “1.1 Setup Flow” for
detailed information.
CHECK:
・*2 Regarding a port number for WS-Man communication, refer to “Appendix C. Port
number for WS-Man communication”.
IMPORTANT:
・If BMC(EXPRESSSCOPE Engine) management is disabled, NEC ESMPRO Manager
connot monitor HW status. Detailed information is shown in the connection check
result screen.
(4) Click “Add”.
(5)Click the “Connection Setting” from “Setting” tab of the managed component.
.Click “Check Connection” to collect the VMware ESXi5 server information for the management
When the “Check Connection” is completed, the NEC ESMPRO Manager starts to control the VMware
ESXi5 server
Detected Detail
Detected The feature was detected.
NEC ESMPRO Manager can use the feature to manage the component.
Not Detected The feature was not detected.
NEC ESMPRO Manager cannot use the feature to manage the component.