NEC ESMPRO Manager Setup Guide
79
CHECK:
・Place the configuration information FD in the write-enable state
3.2.2.2 Run NEC EXPRESSBUILDER DOS based with remote console feature
Configure the BMC of the managed component with the configuration information.
Insert the NEC EXPRESSBUILDER CD-ROM into the CD-ROM drive and the "configuration
information FD" into the FD drive on the managed component. And then turn on the component.
After NEC EXPRESSBUILDER DOS based with remote console feature is started and the
configuration information is loaded from the FD into the managed component, the Operating System
will be rebooted.
TIPS:
・If the setting in the configuration information file is already configured, the managed
component will be not rebooted.
When the console-less function for direct connection is used, the BIOS settings are
changed as follows:
Serial Port Address: On Board COM B
Baud Rate: 19.2kbps
Flow Control: RTS/CTS for the managed server supporting SOL
No Flow for the managed server not supporting SOL
Terminal Type (Console Type) : PC-ANSI
To check whether that the managed server supports SOL, see "Appendix C.
Managed Components Summary"
The managed component is still opened the main menu of the NEC
EXPRESSBUILDER after executing the feature.
After registering the managed component on the NEC ESMPRO Manager and
confirm the remote console for the managed component, remove the NEC
EXPRESSBUILDER from the CD-ROM drive if you need.
3.3 Register the managed component on NEC ESMPRO
Manager
(for modem/direct connection)
Register the managed component on the NEC ESMPRO Manager, perform the "Check Connection".
Login to the NEC ESMPRO Manager and perform the following:
(1) Add the group to which the managed component will belong.
(2) Register a managed component.
3.3.1 Add Group to which the managed component will belong
See 2.3.1"Add Group to which the managed component will belong".
3.3.2 Register the Managed Component (for modem/direct connection)
Click the managed component's "Group name" on the "Group" tree.