System Upgrade 8-17
5. Close the release levers.
IMPORTANT: Unless the release levers are located inside the rack frame, the
module won’t be mounted correctly.
6. Screw the release levers.
7. Boot the installed CPU module.
The system is defaulted to automatically boot the CPU module, once installed.
If the automatic feature is disabled, boot the CPU module using the ft server utility of the
NEC ESMPRO Agent installed to the server or the Data Viewer of the NEC ESMPRO
Manager.
For the detailed procedure, see "NEC ESMPRO Agent and Manager" - "Maintenance of
NEC Express5800/ft series" in Chapter 5.
NEC ESMPRO Manager
Select [FTServer] [CPU Module] [(installed)
CPU Module] [Maintenance] [Bring Up/Bring
Down] [Bring Up].
ft server utility
Select [ft server] [CPU Module] [(installed)
CPU Module] [CPU Module Start/Stop]
[Start].