Seite 1

N8800-124F, EXP320J NEC Express5800/320Fd-LR N8800-125F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 10-2008 856-1

Seite 2

N8815-005, ft remote management card, adopts the DVC technology of Avocent US. The patent numbers for the DVC technology of Avocent US. US Patent Nu

Seite 3 - Safety Indications

4-40 Linux Setup It shows that the new RAID device md4 successfully constitutes the added partitions /dev/sda6 and /dev/sdd6. To create more, repe

Seite 4 - Prohibited actions

Linux Setup 4-41 Step 11: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation of the NEC Express5800/ft series. It

Seite 5 - LASER PRODUCT

4-42 Linux Setup Step 12: Enable OS Boot Monitoring Function When necessary for system operation, enable the “OS Boot Monitoring” setting which has

Seite 6 - 安全標示

Linux Setup 4-43 Step 13: Back up System Information After setting up the system, back up the system information using the Off-line Maintenance Utili

Seite 7 - 本書及警告標籤中使用的符號

4-44 Linux Setup (本页保留空白)

Seite 8

Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system informatio

Seite 9

5-2 Procedures after Completion of Installation INSTALLING MANAGEMENT UTILITIES The provided "NEC EXPRESSBUILDER" DVD contains "NEC

Seite 10

Procedures after Completion of Installation 5-3 NEC ESMPRO Agent NEC ESMPRO Agent is a utility to monitor the operating status, the configurati

Seite 11

5-4 Procedures after Completion of Installation - elfutils-devel-static - lm_sensors - net-snmp-libs - perl - rpm-devel - tcp_wrappers - compat-li

Seite 12 - Preface

Procedures after Completion of Installation 5-5 - libselinux-devel - libsepol-devel - sqlite-devel - beecrypt-devel - elfutils-devel - elfutils-de

Seite 14 - 關於正式文本的再購買

5-6 Procedures after Completion of Installation Correct the environment setting using the vi command, etc., referring to the following. For detai

Seite 15

Procedures after Completion of Installation 5-7 SELinux status: enabled <-Please check here.:

Seite 16

5-8 Procedures after Completion of Installation Installation procedure 1. Log in to the system as a root user. 2. Set the NEC EXPRESSBUILDER to t

Seite 17 - Chapter 1

Procedures after Completion of Installation 5-9 Uninstallation procedure 1. Log in to the system as a root user. 2. Run the following command to

Seite 18 - 1-2 Before Using

5-10 Procedures after Completion of Installation Setup of NEC ESMPRO Agent Follow the instructions below to setup the NEC ESMPRO Agent. 1. Log in

Seite 19 - NOTES FOR SAFE HANDLING

Procedures after Completion of Installation 5-11 Report Setting To report from the NEC ESMPRO Agent to the NEC ESMPRO Manager, you need to set the

Seite 20 - 為了把有為了安全對待的注

5-12 Procedures after Completion of Installation 6. Select [Manager (SNMP)]. The [SNMP Trap Setting] screen will appear. 7. Enable [Enable t

Seite 21 - PRECAUTIONS FOR SAFETY

Procedures after Completion of Installation 5-13 NEC ESMPRO Manager Linked with NEC ESMPRO Agent installed in the server, NEC ESMPRO Manager monit

Seite 22 - 1-6 Before Using

5-14 Procedures after Completion of Installation Confirmation of the Kernel Version The following describes how to check the version of the kernel

Seite 23 - Before Using 1-7

Procedures after Completion of Installation 5-15 Confirmation of the ft Server Control Software Version The following describes how to check the v

Seite 24

ii Preface Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in ter

Seite 25 - During Operation

5-16 Procedures after Completion of Installation (This page is intentionally left blank.)

Seite 26 - Rack-mount Model

Chapter 6 SYSTEM REPAIR For RAID repair procedures upon disk failure, see the User’s Guide “Disk Operation” in the “Chapter 3 Linux Setup and Operat

Seite 27 - Before Using 1-11

6-2 SYSTEM REPAIR TROUBLESHOOTING This section describes what you should do when a trouble occurs in the product. Problems with NEC EXPRESSBUILDE

Seite 28 - 1-12 Before Using

Appendix A About Services Information on NEC Express5800/ft series is provided the web at NEC Express5800 Web ASIA PACIFIC http://www.nec.co.jp/expre

Seite 31 - 安裝,移動,保管及連接注意事項

N8800-124F, EXP320J NEC Express5800/320Fd-LR N8800-125F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 2nd Edition 10-2008 8

Seite 32 - CAUTION

iii About This User’s Guide This User's Guide helps a user to properly setup and use the product. Consult this guide when you set up the product

Seite 33 - 整理及操作內部設備時的注意事項

iv 關於正式文本 使正式文本,是為了確實安裝本裝置,能使用的輔導。進行安裝的時候請利用。使正式文本及另冊的用戶指南請經常放置在實體旁邊無論什麼時候能看。 正式文本,作為所說的關於 Windows 等的操作系統和鍵盤,鼠標的一般的輸入輸出設備等的基本的處理有了充分的知識的用戶對象被記載。 正

Seite 34 - 1-18 Before Using

v Contents Preface...i

Seite 35 - 機架式伺服器的注意事項

vi Step 5: Post OS Install Settings... 4-18 Step 6: Install Software N

Seite 36 - UNPACKAGING

Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go

Seite 37 - 確認箱子的內容的

1-2 Before Using 在使用前 為了把本裝置做為安全確實變成使用必要的關於信息,實體及附屬品等記載著。在安裝實體之前,必定請讀。同時,關於本文中的名稱請參照用戶指南的「與各部分的名稱功能」的項

Seite 38

Before Using 1-3 NOTES FOR SAFE HANDLING The following section describes necessary information to use the product properly and safely. Warning Label

Seite 39 - Chapter 2

PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable

Seite 40 - About OS Reinstallation

1-4 Before Using 為了把有為了安全對待的注 意的本裝置做為安全確實變成使用必要的信息被記載。 關於警告標籤 隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候, 經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼,

Seite 41 - Chapter 3

Before Using 1-5 PRECAUTIONS FOR SAFETY This section provides precautions for using the server safely. Read this section carefully to ensure proper a

Seite 42 - INSTALLATION

1-6 Before Using Use of Power Supply and Power Cord WARNING Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a w

Seite 43

Before Using 1-7 Installation, Relocation, Storage and Connection CAUTION Do not install the server in an unsuitable place. Install the serve

Seite 44 - 3-4 Installing Server

1-8 Before Using Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein,

Seite 45

Before Using 1-9 CAUTION Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protecti

Seite 46 - Back side of 4U chassis

1-10 Before Using Rack-mount Model WARNING Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming

Seite 47

Before Using 1-11 CAUTION Do not install excessive wiring. To prevent burns, fires, and damage to the server, make sure that the rated load o

Seite 48 - Core nuts

1-12 Before Using 安全注意事項 本節講述安全使用本伺服器所需的注意事項。為了您正確安全地使用本伺服器,請仔細閱讀該節內容。符號的相關說明請參考“安全標示(SAFETY INDICATIONS)"說明。 一般注意事項 WARNING 不要用於危及人命和需要高度可靠性的操作

Seite 49

Before Using 1-13 使用電源及電源線注意事項 WARNING 不要用濕手拿電源插頭。 不要用濕手插拔電源插頭。有觸電的危險。 不要把地線連接到煤氣管道上。 請勿將地線連接到煤氣管道上。有導致煤氣爆炸的危險。 CAUTION 不要插入未指定的插座。

Seite 50

Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 series safely, follow the instructi

Seite 51

1-14 Before Using 3極點用的電源插座以外不使用。 被本裝置添加的電源編碼拿第3大頭針(earth pin)的3極點插頭被裝備。這個插頭,只3極點用的電源插座能使用。使用那個以外的電源插座的話,有觸電的可能。 其他的裝置和用途不使用添加的電源編碼 添加的電源編碼作為目的

Seite 52

Before Using 1-15 安裝,移動,保管及連接注意事項 CAUTION 不要安裝或存放在未指定的場所。 不要將本設備放置在如下場所和本書未指定的場所,有導致火災的危險。  灰塵較多的場所  熱水器旁等濕氣較高的場所  陽光直射的場所  不平穩的場所 不

Seite 53

1-16 Before Using CAUTION 不要使用未指定的信號線。 使用NEC指定的信號線,並在確認連接設備和介面後進行連接。使用未指定信號線或連接錯誤等會造成短路、導致火災。 信號線的操作和連接,須遵守以下注意事項:  不要使用任何損壞的信號線接頭。  不要踩踏信號

Seite 54

Before Using 1-17 整理及操作內部設備時的注意事項 WARNING 不要自行拆卸、修理或改造本伺服器。 除本書記載的情況外,不要進行拆卸、修理、改造。否則,不但可能導致設備不能進行正常運行,還有發生觸電和火災的危險。 不要看光碟機內部。 光碟機使用了雷射,

Seite 55

1-18 Before Using CAUTION 請用保護蓋保護好未使用的介面。 請用保護蓋保護好未使用的電源線介面以防止短路或觸電。從內部設備上拔下電源插頭時,用保護蓋蓋好介面,否則有導致火災或觸電的危險。 操作注意事項 CAUTION 不要在打雷時觸摸機器。 打雷

Seite 56

Before Using 1-19 機架式伺服器的注意事項 CAUTION 不要將設備安裝在未指定的機架上。 請將設備安裝在符合EIA標準的19英寸機架上。一定要將設備安裝在指定的機架上才能使用。否則設備可能無法正常使用,並有可能損壞機器零部件或導致人身傷害。關於合適的機架,請與您的經銷

Seite 57

1-20 Before Using UNPACKAGING This product and various accessories are in the special shipping box. Take them out from the box and check the individu

Seite 58

Before Using 1-21 確認箱子的內容的 本產品和附屬品進入著專用的捆包箱子。從箱子取出各自檢點。捆包箱子和有餘了的附屬品請最後一幕保管。關於附屬品本 關於附屬品本 產品的捆包箱子的其中,對實體以外種種的附屬品進入著。確認參照添加的構成品表全部齊(整)的事,請各自檢查。萬一不足的如果

Seite 59

1-22 Before Using (This page is intentionally left blank.)

Seite 60

Chapter 2 About Operating System This chapter gives essential information on the Linux system supported by the server and how to install it.

Seite 61 - Chapter 4

Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicate

Seite 62 - Before starting Setup

2-2 About Operating System Red Hat Enterprise Linux Advanced Platform 5.2 For installing an operating system on NEC Express5800/ft series, follow “Ch

Seite 63 - SETUP FLOW

Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express58

Seite 64

3-2 Installing Server INSTALLATION This section describes installation of NEC Express5800/ft series. Rack-mount Model You can mount NEC Express5800/

Seite 65 - DISK ACCSSS LED

Installing Server 3-3 WARNING Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details

Seite 66

3-4 Installing Server  Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you m

Seite 67 - CHECK:

Installing Server 3-5 Installing the device to the rack (N8140-74/92/93/94/98/99) Install this device to the rack. Installing the device to our comp

Seite 68

3-6 Installing Server ● Checking the place to install Decide the place (height) to install. To keep balance, install it as low as you can on the rac

Seite 69

Installing Server 3-7 TIPS: Core nuts (8 pieces) are not included. Use the core nuts that are attached to the rack. 1. If the rack has front and r

Seite 70

3-8 Installing Server 3. Fix the core nuts to the front side of the rack. Attach them symmetrically (total: 8 core nuts). Fix a cor

Seite 71

Installing Server 3-9 5. Tentatively fasten the washers and plate screws (short) to the 4 places on the front and back sides (total: 8) from the rea

Seite 72

Mandatory actions Unplug the server. There is a risk of an electric shock or fire. Indicates a general action to take that is not defined herein. M

Seite 73

3-10 Installing Server 7. Fasten tightly the 4 round screws on the back side and the 8 plate screws on the side panels (which you fastened tentative

Seite 74

Installing Server 3-11 9. Return the locks on the left and right. 10. Fasten the levers on the left and right sides with screws.

Seite 75

3-12 Installing Server Unmounting the device from the rack (N8140-74/92/93/94/98/99) Follow the steps below and unmount the device from the rack. CA

Seite 76

Installing Server 3-13 Installing the Tower Conversion Kit (N8843-002) This section describes how to install the rack-mount model of NEC Express5800

Seite 77

3-14 Installing Server Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction.  Place where

Seite 78 - Initial Configuration Script

Installing Server 3-15 Steps to Install the Rack-mount Model to the Tower Conversion Kit Follow the procedure below to install the devices to the tow

Seite 79

3-16 Installing Server 4. Fix the bracket with four washers and countersunk screws (long ones), two at the top and two at the bottom.

Seite 80

Installing Server 3-17 If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further insid

Seite 81

3-18 Installing Server Connect Peripheral Devices to NEC Express5800/ft Series The server provides connectors for a wide variety of peripheral device

Seite 82

Installing Server 3-19 IMPORTANT: Connection of optional devices  In the case of standard configuration, you need to complete setup of the operat

Seite 83 - Network Configuration

安全注意事項 安全標示 請參考本用戶指南中的指示以安全使用NEC Express5800系列伺服器。 本用戶指南說明了設備何處有危險、危險類型、如何避免危險等。在設備可預計到的危險之處或其附近貼有警告標籤。 用戶指南及警告標籤中,根據危險程度不同,使用“警告"、“注意"等詞,含義如下

Seite 84 - Dual Configuration Setup

3-20 Installing Server Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit. Connect the plug at the other e

Seite 85 - GATEWAY=192.168.0.1

Chapter 4 Linux Setup This chapter describes procedures for configuring OS Boot Monitoring function, setting dual LAN configuration, setting dual dis

Seite 86

4-2 Linux Setup Before starting Setup Read this section before starting setup. Use Red Hat Enterprise Linux Advanced Platform 5.2 and Red Hat Enter

Seite 87 - Disk Configuration

Linux Setup 4-3 SETUP FLOW The right flow-chart illustrates the flow of the setup procedures for the NEC Express5800/320Fd-MR server. Corresponding

Seite 88

4-4 Linux Setup Step 1: Things Required for Setup The following explains the setup procedure using the Express Setup program: IMPORTANT:  NEC Exp

Seite 89

Linux Setup 4-5 Step 2: Prepare for Express Setup Before install LINUX server, be sure to do the following. If these preparations are not done, setup

Seite 90 - Verifying duplication

4-6 Linux Setup When the AC power is on (The power cords are plugged to the wall outlet) (1) Confirm the POWER LED of the

Seite 91

Linux Setup 4-7 Step 3: Disable OS Boot Monitoring Function Check whether the power is ON and make settings for properly performing setup for later o

Seite 92

4-8 Linux Setup 3. Press the POWER switch which is located on the front side of the server. (This is the side on which the in-built LED is lit.)

Seite 93 - Fast Resync Function

Linux Setup 4-9 Main Advanced Security Server Boot Exit ftServer Setup F1 Help ↑↓ Select Item -/+ Change Values

Seite 94 - Creating Striping Array

本書及警告標籤中使用的符號 注意 表示有觸電的危險。 表示有因高溫而負傷的危險。 表示有手指等被夾住的危險。 表示有冒煙或者著火的危險。 表示非特定的一般的提醒警告。 表示有因雷射導致失明的危險。 表示有爆炸的危險。 表示有受傷的危險。 禁止行為 表示非特定的一般禁止。 不

Seite 95

4-10 Linux Setup 5. Move the cursor onto "Server" and select “Server.” The Server menu will be displayed. 6. Move the cursor onto

Seite 96

Linux Setup 4-11 7. Move the cursor onto “OS Boot Monitoring” and press Enter. Parameters will be displayed. 8. Among the parameters, choose “Disa

Seite 97

4-12 Linux Setup 9. Press the Esc key to go back to the Server menu, and then move the cursor and select "Exit" to display the Exit menu.

Seite 98 - Step 10: Create Volume

Linux Setup 4-13 Step 4: Install Red Hat Enterprise Linux Advanced Platform 5.2 In NEC Express5800/ft series, all the internal disks configure RAID1

Seite 99

4-14 Linux Setup After this, consult the Red Hat Enterprise Linux Advanced Platform 5.2 manual to install Red Hat Enterprise Linux Advanced Platform

Seite 100 - 4-40 Linux Setup

Linux Setup 4-15 IMPORTANT: <Partition Layout> Make sure to create a software RAID partition exactly as one of the following patterns; otherwi

Seite 101

4-16 Linux Setup system. You can check the swap usage by free command while running the system. You need to consider expanding the swap partition or

Seite 102

Linux Setup 4-17 libXext-1.0.1-2.1.x86_64.rpm libXi-1.0.1-3.1.x86_64.rpm libXp-1.0.0-8.1.el5.x86_64.rpm libXt-1.0.2-3.1.fc6.x86_64.rpm libXtst-1.0.1-

Seite 103

4-18 Linux Setup Step 5: Post OS Install Settings Initial Configuration Script Run the initial configuration script after installing Red Hat Enterp

Seite 104 - (本页保留空白)

Linux Setup 4-19 Step 6: Install Software NEC Express5800/ft Series offers Install the software provided by NEC Express5800/ft series by the followi

Seite 105 - Chapter 5

強制行為 請將本設備的電源插頭從伺服器上拔下。有發生火災和觸電的危險。 對非特定的一般使用者的行為進行指示。請按照說明進行操作。 這是CLASS 1 LASER PRODUCT。該標籤貼於系統的內部光碟。 注意: 本產品通過多餘的硬體模組提供硬體容錯性能。但是這並不表示能夠保

Seite 106

4-20 Linux Setup 3. Install java-1.5.0-sun. # rpm -ivh --nosignature /mnt/Supplimentary/java-1.5.0-sun-1.5.015-1jpp.2.el5.x86_64.rpm 4. Enter the

Seite 107 - NEC ESMPRO Agent

Linux Setup 4-21 NEC ESMPRO Agent IMPORTANT: Read “5-4 Preparation before Setup” before install and setup. 1. Login as a root user. 2. Set and mo

Seite 108 - IMPORTANT:

4-22 Linux Setup Processes made on esminst.sh esminst.sh executes and processes the below. 1. snmpd environment setting 2. portmap boot settin

Seite 109

Linux Setup 4-23 Step 7: Set Dual LAN Configuration NEC Express5800/ft series uses Bonding for duplex of 1000 BASE LAN cards controlled by the e1000

Seite 110

4-24 Linux Setup Dual Configuration Setup The following describes the procedure to set dual LAN configuration. The following example is used. Sinc

Seite 111

Linux Setup 4-25 GATEWAY=192.168.0.1

Seite 112 - Processes made on esminst.sh

4-26 Linux Setup 3. Execute the command below to activate the combined interface that has been constructed. # vndctl up 3 4. Execute the command

Seite 113 - Uninstallation procedure

Linux Setup 4-27 Step 8: Set Dual Disk Configuration At this point, CPU/IO module 1 - Slot 1 and CPU/IO module 0 - Slot 1 have been duplex. Except wh

Seite 114 - Setup of NEC ESMPRO Agent

4-28 Linux Setup IMPORTANT:  When a disk is added or RAID is reconfigured, the status of each disk becomes “RESYNC”, “RECOVERY”, “CHECK” or “REPA

Seite 115 - Report Setting

Linux Setup 4-29 3 - 4 sdd(sdj) [3] AAA/BBB/#DDD h6c0t128l0 5 - 6 - <Explanation of items> Slo

Seite 116

Trademarks and Patents NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Ser

Seite 117 - NEC ESMPRO Manager

4-30 Linux Setup *1 Enter the number of partitions to be created. Then enter the size for each partition by MB. The remainder is automatically all

Seite 118

Linux Setup 4-31 <Explanation of items> Name Name of the software RAID device Partition Mount point When this is blank, it means the parti

Seite 119

4-32 Linux Setup 1. Execute “Configurations” in ftdiskadm and select “DISK_SCRUBBING_INTERVAL” from the setting menu. # ftdiskadm Command action

Seite 120

Linux Setup 4-33 Fast Resync Function This function shortens the recovery time of partitions in the internal hard disk drives when the partitions ar

Seite 121 - Chapter 6

4-34 Linux Setup Creating Striping Array Striping array (RAID 0) is a RAID device that distributes I/O requests issued to striping array to each mem

Seite 122 - TROUBLESHOOTING

Linux Setup 4-35 md0 /boot ( - ) DUPLEX (1)sda1 (4)sdd1 md1 swap ( - ) DUPLEX (1)sda2

Seite 123 - Appendix A

4-36 Linux Setup 3. After the procedure 2., the screen shows the message that the process is going on. If the screen does not show any error and go

Seite 124

Linux Setup 4-37 Step 9: Connect and Configure Options If there is any optional PCI board or peripheral equipment to connect to NEC Express5800/ft se

Seite 125

4-38 Linux Setup Step 10: Create Volume If there is free disk space in the internal disk with the OS, you can create a volume. To create a volume i

Seite 126 - User's Guide (Setup)

Linux Setup 4-39 “t”.>>> Command (m for help): n First cylinder (8382-8899, default 8382): Using default value 8382 Last cylinder or +size