Seitenansicht 67
6-8
Series3800/S120R-2 (6025B-3/6025B-3R) User's Manual
6-5 Power Supply
6025B-3
The Series3800/S120R-2 (6025B-3) has a single 560 watt power supply, which is
auto-switching capable. This enables it to automatically sense and operate with a
100v - 240v input voltage.
Power Supply Failure
If the power supply module fails, the system will shut down and you will need to
replace the module. As the power supply module in the 6025B-3 is not cold-swap-
pable, you will need to remove the chassis cover and disconnect all power cables
from the power supply unit before removing and replacing the power supply.
Removing/Replacing the Power Supply
1. Removing the power supply
First unplug the power cord from the power supply module. Remove the cover
from the chassis and disconnect all power cables from the motherboard and any
components. Then remove the screws that secure the power module to the chas-
sis. Finally, pull the module straight out by the handle.
2. Installing a new power supply
Replace the failed power supply with an identical power supply module (p/n PWS-
561-1H). Reconnect all power cables from the power supply to the motherboard and
components. Replace the chassis cover and reconnect the AC power cord. Finish
by depressing the power button on the chassis front control panel to restart the
system. has a single 550 watt power supply, which is auto-switching capable. This
enables it to automatically sense and operate with a 100v - 240v input voltage.