114
4-2 Manual Rebuild
Described below is the rebuild procedure when one of the HDD fails in a RAID1 virtual disk configured with
two HDD‟s.Replace the failed HDD with a new one after turning off the power of the server. The Auto Rebuild
feature is disabled for non-hot-swap replacement. Use the Manual Rebuild feature to recover the virtual disk
as described below:
1. Start WebBIOS.
Make sure that the status for the replaced HDD is indicated as "UNCONF GOOD" in the right frame
of the top menu.
2. Make sure that the HDD that has been installed in slot 1 is missing.
3. Select "PD2" (newly connected HDD) in [Physical Drives].
The properties for the physical drive are displayed.
4. Select "Make Global HSP" from the lower right of the screen, and then click [Go] at the lower center
of the screen.