NEC PD Comms Tool Betriebsanweisung Seite 50

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 49
Direct LAN
Supported display connection congurations
RS-232C
IN
RS-232C
OUT
LAN
RS-232C IN, OUT, and LAN
LAN1 LAN2
RS-232C
RS-232C IN, LAN 1 and LAN2
Models that have an RJ45 LAN connection can be individually connected directly to a LAN via a hub or switch instead
of daisy-chaining displays together. This may require more wiring since each display is individually connected directly
to a central LAN hub or switch. The advantages of using this method is that communications to other displays will still
function even if:
A display is removed from the system without bridging the daisy-chain.
A display looses AC power or is turned off via the display’s main power switch.
A display fails.
There is a fault in cabling to an individual display.
A display enters standby power mode and the LAN POWER setting is set to OFF (models that support LAN
daisy-chain only).
See “Example: Direct Multi IP LAN” on page 56.
Important points to note:
Each display must have a unique IP address.
Since each display is addressed by the combination of IP address and Monitor ID, each display can have the
same or unique Monitor IDs.
RS232 Daisy-chain
Supported display connection congurations
RS-232C
IN
RS-232C
OUT
RS-232C IN and OUT
RS-232C
IN
RS-232C
OUT
LAN
RS-232C IN, OUT, and LAN
Models that have two RS232 connections (not including any RS232 connections on OPS devices), support RS232
daisy-chaining. The connection labeled IN is the input to the display from the host PC. The other connection labeled
OUT is the output to connect to the IN on the next display in the daisy chain.
See “Example: Single IP LAN with daisy-chained RS232” on page 55 and “Example: Daisy-chained RS232 with one
COM port” on page 53.
Important points to note:
When using RS232 to connect displays using a daisy-chain, each display on the chain must have a unique
Monitor ID (set via the display’s OSD).
Displays must be connected using an RS232 serial NULL modem cable (also known as a “crossover” cable).
The rst display in the daisy-chain can be connected to the host PC either via RS232, or by LAN if the model has
an RJ45 LAN connection (not including any RJ45 LAN connections on OPS devices). When connected via LAN,
the rst display can forward commands received over LAN to other displays in the RS232 daisy-chain.
50 | NEC PD COMMS TOOL - USER’S GUIDE
Seitenansicht 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 61 62

Kommentare zu diesen Handbüchern

Keine Kommentare