Example Display Connections
Conguring Connections
Displays can be connected to the host PC in a variety of ways using RS232 or LAN, depending on the model.
Displays can also be daisy-chained together using RS232 or LAN cables, depending on the model. Daisy-chaining
displays can simplify cable wiring, and allows more than one display to be controlled from one access connection, as
well as minimizing the lengths and number of cable runs.
The following table shows the types of daisy-chains available depending on the connection conguration of the display
model being used.
Display connection
conguration
Connection description Daisy-chain type Input connection to rst
display in daisy-chain
RS-232C
IN
RS-232C
OUT
RS-232C IN and OUT RS232 RS232
RS-232C
IN
RS-232C
OUT
LAN
RS-232C IN, OUT, and LAN RS232 LAN or RS232 (selectable)
LAN1 LAN2
RS-232C
RS-232C IN, LAN 1 and LAN2 LAN LAN or RS232
To determine the correct display connection conguration for each display model:
Look at the physical connections on the display.
Refer to the display’s User’s Manual.
About Monitor IDs
Each display has a Monitor ID number that is used to individually identify and address it when
used in a daisy-chain.
Each display in a daisy-chain must have a unique Monitor ID.
The Monitor ID is congured via the OSD. Models that support LAN daisy-chains can have the
Monitor ID set automatically using the Auto ID function. See “Using the Auto ID function with a LAN
daisy-chain” on page 52 and the display Users Manual for more information.
The Monitor ID congured in the software must match the Monitor ID on each display.
Monitor IDs also allow displays to be individually controlled from a single IR remote control. See