5
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method
0322
(40000142)
Information [Address Type 2 ] Rebuild was resumed. R
0323
(40000143)
Information [Address Type 2 ] Rebuild was queued. R
0324
(80000144)
Warning [Address Type 2 ] Medium Error was detected in Physical
Device. %1
%1 : Logical Block Address
RO MA Physical Device Medium
Error Detected
Please replace the Physical Device if too many errors
are detected on a Physical Device.
0401
(40000191)
Information [Address Type 3 ] Logical Drive is Online. RO M Logical Drive Online None
0402
(80000192)
Warning [Address Type 3 ] Logical Drive is Degraded. RO MA Logical Drive Degraded If there is Hot Spare, RA
ID System will rebuild
automatically. If there is not it, please replace the
Physical Device and rebuild it.
0403
(C0000193)
Fatal [Address Type 3 ] Logical Drive is Offline. RO MA Logical Drive Offline Please replace the Physical Device and remake the
Logical Drive. Next restore the backup data to the
Logical Drive.
(40000194)
[Address Type 3 ] Initialization was started.
0405
(40000195)
Information [Address Type 3 ] Initialization completed. R
0406
(C0000196)
Fatal [Address Type 3 ] Initialization failed. RO MA Initialization Failed Please retry Initialization. If Initialization failed
repeatedly, the RAID System may have some kind of
problem. Please deal with the problem of the RAID
System.
0407
(40000197)
Information [Address Type 3 ] Initialization was stopped. R
(40000199)
[Address Type 3 ] Consistency Check was started.
0410
(4000019A)
Information [Address Type 3 ] Consistency Check completed. R
0411
(C000019B)
Fatal [Address Type 3 ] Consistency Check failed. RO MA Consistency Check Failed Please retry Consistency Check. If Consistency Check
failed repeatedly, the RAID System may have some kind
of problem. Please deal with the problem of the RAID
System.
0412
(4000019C)
Information [Address Type 3 ] Consistency Check was stopped. R
Kommentare zu diesen Handbüchern