1. In [Configuration] section, specify parameters.
- In ˝Timeout ˝, specify number of seconds to stop collecting failure information.
- In ˝MaxSize ˝, specify maximal size of collecting failure information log (count by KB).
- In the case of 0 “Timeout”,”MaxSize is unlimited.
2. In [DefaultTools] section, specify log information for the case of not specifying
individual log commands.
- In ˝Command ˝, specify the absolute path of log command.
- In ˝Directory ˝, specify the absolute path where the log-gathering command is executed.
- In ˝LogFile ˝, specify the absolute path. When a folder is specified, the files under it
(includes subfolders) are collected.
3. In [NoneTrouble] section, specify events that are not the targets for log-gathering.
- Specify the events as ˝SourceNameXX ˝, ˝EventIDXX ˝ (˝XX ˝ is any of the sequence
number from ˝01 to 99 ˝).
- In ˝SourceNameXX ˝ specify the source name of the target. When ˝* ˝ is given, all source
name are specified.
- In ˝EventIDXX ˝, specify target event ID.
- Specify the event ID, all 32 bytes events, in hexadecimal beginning with ˝0x ˝. Multiple
event IDs can be given, separated by ˝, ˝. When ˝* ˝ is given, all event IDs are specified.