N8800-063E/064E NEC Express5800/320Lc/320Lc-R User's Guide (Setup) 1st Edition 12-2004 856-124610-001-A

Seite 2

iv Contents Preface...

Seite 4

Error! Style not defined. 4-57 Step 13: Back up System Information After setting up the system, back up the system information using the Off-line Mai

Seite 5

4-58 Windows Setup (This page is intentionally left blank.)

Seite 6

Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system informatio

Seite 7 - Preface

5-2 Procedures after Completion of Installation Installing Management Utilities The provided "NEC EXPRESSBUILDER" CD-ROM contains "NE

Seite 8 - About This User’s Guide

Procedures after Completion of Installation 5-3 Operation Environment NEC ESMPRO Agent can be operated in the hardware and software environments sho

Seite 9 - Additional symbols

5-4 Procedures after Completion of Installation 4. Enter “public” in the [Community name] box in the [Traps] property sheet and click the [Add to l

Seite 10 - Contents

Procedures after Completion of Installation 5-5 IMPORTANT:  If the community name is changed, the community of NEC ESMPRO Agent is changed and re

Seite 11

5-6 Procedures after Completion of Installation Installation NEC ESMPRO Agent is automatically installed together with the installation or re-instal

Seite 12

Procedures after Completion of Installation 5-7 4. Click [Agent] in the main menu of the NEC ESMPRO setup. TIPS: The available menus vary depe

Seite 13 - Chapter 1

v 2-1: Initialize Hard Disks...4-6 2-2: Prep

Seite 14 - Notes for Safe Handling

5-8 Procedures after Completion of Installation 7. Enter the path in which NEC ESMPRO Agent is installed and click the [Next] button. The NEC ESMPR

Seite 15 - Before Using 1-3

Procedures after Completion of Installation 5-9 Setup of NEC ESMPRO Agent The settings of installed NEC ESMPRO Agent remain unchanged from those at

Seite 16 - Rack-mount Model

5-10 Procedures after Completion of Installation Uninstall The configuration of NEC ESMPRO Agent and BMC and the uninstallation of BMC FW Update Ser

Seite 17 - 会引起触电等事故。

Procedures after Completion of Installation 5-11 Uninstallation of BMC Configuration and BMC FW Update Service If NEC ESMPRO Agent is installed, the

Seite 18 - PCI/CPU Modules

5-12 Procedures after Completion of Installation NEC ESMPRO Manager Linked with NEC ESMPRO Agent installed in the server, NEC ESMPRO Manager monitor

Seite 19 - Precautions for Safety

Procedures after Completion of Installation 5-13 System Requirement The hardware and software environment in which NEC MWA runs is: • Management PC

Seite 20 - 1-8 Before Using

5-14 Procedures after Completion of Installation Setting up PCs on a Network If you have computers running on Windows Server 2003, Windows XP/2000/N

Seite 21 - Before Using 1-9

Procedures after Completion of Installation 5-15 Type: REG_DWORD Set value: 5  Windows 95/98/Me: Registry key: HKEY_LOCAL_MACHINE\SYSTEM\CurrentC

Seite 22 - 1-10 Before Using

5-16 Procedures after Completion of Installation Confirmation of the ft Control Software Version The following describes how to check the version of

Seite 23 - Before Using 1-11

Procedures after Completion of Installation 5-17 Notes to apply the Windows Service Pack Customers should not apply service pack on NEC Express5800/

Seite 24 - 1-12 Before Using

vi System Repair...6-2 P

Seite 25 - Before Using 1-13

Chapter 6 Troubleshooting This chapter describes what to do when files needed to operate the OS are damaged and any trouble occurs on the product.

Seite 26 - During Operation

6-2 Troubleshooting System Repair If the system cannot be operated by some reason, use Recovery Console to restore the system. However, this method

Seite 27

Troubleshooting 6-3 If you have a computer that runs Windows Server 2003, Windows 2000/XP/NT or Windows 95/98/Me. You can also create a “Windows Ser

Seite 28 - Unpackaging

6-4 Troubleshooting Please select the operating system to start: Windows Server 2003, Enterprise Microsoft Windows Recovery Console Starting up Rec

Seite 29 - Chapter 2

Troubleshooting 6-5 <When starting Recovery Console from Windows Server 2003 CD-ROM> (a) Insert the Windows Server 2003 CD-ROM into the drive

Seite 30 - About OS installation

6-6 Troubleshooting (b) Insert the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” into the floppy disk drive, and then press Enter. (c) Sp

Seite 31

Troubleshooting 6-7 (b) Insert the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” into the floppy disk drive, and then press Enter. (c)

Seite 32 - 2-4 About Operating System

6-8 Troubleshooting Welcome to Setup. This portion of the Setup program prepares Microsoft(R) Windows(R) to run on your computer. - To set up Wind

Seite 33 - Chapter 3

Troubleshooting 6-9 Updating the System IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to upda

Seite 34

6-10 Troubleshooting <For on-board > - Status emb-82559 10/100 Enet Adapter - Status emb-82544GC Copper Gigabit Adapter <For option boar

Seite 35

Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go

Seite 36

Troubleshooting 6-11 At that time, the dialog box shown on the right is displayed. This is a message for confirmation, so click the [Yes] button. Re

Seite 37

6-12 Troubleshooting 3) Select [Intel(R) PROSet II] from a list of [Currently installed programs:]. 4) Click [Change/Remove]. At that t

Seite 38

Troubleshooting 6-13 4. After rebooting the system, log on to the system as a user with Administrative account. IMPORTANT: Check the dual system is

Seite 39

6-14 Troubleshooting (Conditions) The dialog appears when the drive, whose available space is the biggest in the NTFS volumes recognized by the sys

Seite 40 - Connection

Troubleshooting 6-15 of machine. (See page 4-9 for details.) - If PCI module (for Group2)’s POWER switch is lit green, unplug the power cord conn

Seite 41

6-16 Troubleshooting 9. Start Device Manager, choose [View] then [Device by connection] and do the following: a) Delete the red-circled device ent

Seite 42

Troubleshooting 6-17 a-5. The message of update completion will be displayed. "[Update of the driver Completion] Press any key and terminate.&

Seite 43 - <Example>

6-18 Troubleshooting ←Performed d by mistake←Performed a by mistake ←Performed c by mistake d-3. Run the following command from Command Prompt and

Seite 44 - 3-12 Installing Server

Troubleshooting 6-19 Note: If you restart the system without deleting the disconnected option boards, the following dialog box may appear at startup

Seite 45 - Chapter 4

6-20 Troubleshooting Troubleshooting This section describes what you should do when a trouble occurs in the product. Problems with NEC EXPRESSBUI

Seite 46

1-2 Before Using Notes for Safe Handling The following section describes necessary information to use the product properly and safely. Warning Label

Seite 47 - Setup Flow

Troubleshooting 6-21 Problems with Windows Setup The following message is displayed when the setup starts. The specified disk is not found. Termi

Seite 48

6-22 Troubleshooting “Display Settings” is displayed on lower right of the screen. → Select [Display Properties] – [Settings] tab – [Color Qual

Seite 49

Troubleshooting 6-23 Problems with NEC ESMPRO Setup A menu which cannot be chosen with a setup main menu. → The available menus vary depending on t

Seite 50 - 2-1: Initialize Hard Disks

6-24 Troubleshooting Problems with System Repair Cannot create the “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” with “NEC Express5800/ft se

Seite 51 - Windows Setup 4-7

Troubleshooting 6-25 PROSet II does not start after the system is updated.  Did you reboot the system after breaking dual LAN configuration and un

Seite 52

6-26 Troubleshooting N8800-063F/064F NEC Express5800/320Lc/320Lc-R User's Guide (Setup) 1st Edition 12-2004 856-124610-001- A

Seite 53

Before Using 1-3 Label DLabel C Label E Label A Label B

Seite 54

1-4 Before Using Rack-mount Model Label C Label ALabel BLabel D Label ELabel D Label E Label CLabel B

Seite 55

Before Using 1-5 Label DLabel C Label B Label A Label E 请小心不要夹住或碰伤手指。 设备运行时以及刚切断电源后,硬盘表面温度会很高,请一定注意。 对 CPU 模块、PCI 模块

Seite 56

1-6 Before Using PCI/CPU Modules PCI Module CPU Module Label ALabel ALabel A Label A

Seite 57

Before Using 1-7 Precautions for Safety This section provides precautions for using the server safely. Read this section carefully to ensure proper a

Seite 58

PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable

Seite 59

1-8 Before Using CAUTION Prevent water or foreign objects from getting into the equipment. Do not let water or foreign objects (e.g., pins or p

Seite 60

Before Using 1-9 Use of Power Supply and Power Cord WARNING Do not handle a power plug with a wet hand. Do not plug/unplug a power cord with a we

Seite 61

1-10 Before Using CAUTION Do not use nonconforming power cords. Use the power cords specified by NEC. If the rated current is exceeded, there i

Seite 62

Before Using 1-11 Installation, Relocation, Storage and Connection WARNING Disconnect the power cord(s) before installing or removing the equipment

Seite 63

1-12 Before Using CAUTION Do not connect any interface cable with the power cord of the server plugged to a power source. Make sure to power of

Seite 64

Before Using 1-13 Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, n

Seite 65

1-14 Before Using During Operation CAUTION Do not pull out a device during operation. Do not pull out or remove a device while it works. There is

Seite 66

Before Using 1-15 Rack-mount Model CAUTION Do not attempt to install the server yourself. To avoid a risk of injuries, users should not attempt t

Seite 67

1-16 Before Using Unpackaging The following section describes necessary information to use the product properly and safely. Accessories This product

Seite 68

Chapter 2 About Operating System This chapter gives essential information on the Windows system supported by the server and how to install it.

Seite 69

Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 Series safely, follow the instructi

Seite 70

2-2 About Operating System Installing Windows Server 2003 For installing an operating system on NEC Express5800/ft series, use NEC EXPRESSBUILDER. I

Seite 71

About Operating System 2-3 IMPORTANT:  Complete all the setups such as the memory expansion and the BIOS setting before installing Windows Server

Seite 72

2-4 About Operating System (This page is intentionally left blank.)

Seite 73

Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express58

Seite 74

3-2 Installing Server Installation This section describes installation of NEC Express5800/ft series. Tower Model IMPORTANT: NEC Express5800/ft serie

Seite 75

Installing Server 3-3 Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction.  Place where t

Seite 76

3-4 Installing Server After fastening the main cabinet, open its front bezel to mount the CPU and PCI modules. For details, see the following section

Seite 77

Installing Server 3-5 Installation of Rack-mount Model You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards. IMPO

Seite 78

3-6 Installing Server WARNING Observe the following precautions to use the server safely. There is a risk of a death or serious injury. For details

Seite 79

Installing Server 3-7  Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you mu

Seite 80

Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicate

Seite 81

3-8 Installing Server Connection Connect peripheral devices to NEC Express5800/ft series. The server is provided with connectors for wide variety

Seite 82

Installing Server 3-9 A rack-mount model is shown here. As for a tower model, locations of the connectors are same though the orientation of the equi

Seite 83 - Registering RDR key

3-10 Installing Server After connecting cables to PCI modules, secure them with the cable ties. When completing connection to peripheral equipment, c

Seite 84

Installing Server 3-11 To connect the power cords from the server to an uninterruptible power supply (UPS), use service outlets on the rear of the UP

Seite 85

3-12 Installing Server (This page is intentionally left blank.)

Seite 86

Chapter 4 Windows Setup This chapter describes procedures for configuring boot monitoring function, setup, installing Windows, setting dual LAN confi

Seite 87 - Step 7: Update Software

4-2 Windows Setup ft series Setup Use NEC EXPRESSBUILDER to setup the NEC Express5800/ft series. IMPORTANT: NEC Express5800/ft series is a precision

Seite 88 - Step 9: Create Volume

Windows Setup 4-3 Run [Setup] from NEC EXPRESSBUILDER top menu Prepare for Windows Server2003 Enterprise Edition installation and ft control software

Seite 89

4-4 Windows Setup Step 1: Things Required for Setup The following explains the setup procedure using the ft series setup program: IMPORTANT: Do no

Seite 90

Windows Setup 4-5 Size of the Partition to be Created The required minimum size of a partition to install the system can be obtained from the followi

Seite 91

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These

Seite 92

4-6 Windows Setup Step 2: Prepare for ft series Setup Before starting ft series setup, be sure to do the following. If these preparations are not d

Seite 93

Windows Setup 4-7 11. When restarting process starts, remove the ROM-DOS startup disk from the floppy disk drive and power off. Initialization of ha

Seite 94

4-8 Windows Setup 2-2: Prepare NEC Express5800/ft series With the power of NEC Express5800/ft series off, follow the steps below: 1. Prepare NEC

Seite 95

Windows Setup 4-9 <When the AC power is off (The power cord is not plugged into the outlet)> Connect the power cords to NEC Express5800/ft

Seite 96 - Set Dr. Watson

4-10 Windows Setup (2) Make sure that the two BMC Status LEDs of the PCI modules (for Group1/for Group2) are turned off. IMPORTANT: While the

Seite 97

Windows Setup 4-11 Step 3: Disable Boot Monitoring Function Check whether the power is ON and make settings for properly performing setup for later o

Seite 98 - Install a Network Monitor

4-12 Windows Setup 3. Confirm that the BMC Status LED ( ) on both PCI modules are off and press the illuminated POWER switch which is locat

Seite 99 - Set MTBF Type

Windows Setup 4-13 4. When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to Network” on the

Seite 100 - 4-56 Windows Setup

4-14 Windows Setup 6. Move the cursor onto “Monitoring Configuration” and press Enter. The Monitoring Configuration submenu appears. 7. Mo

Seite 101

Windows Setup 4-15 9. Move the cursor onto "Exit" to display the Exit menu. 10. Move the cursor onto “Save Changes & Exit” and pres

Seite 102 - 4-58 Windows Setup

Trademarks NEC EXPRESSBUILDER, NEC ESMPRO, and NEC Express5800/ft series are trademarks of NEC Corporation. Stratus is a registered trademark of Stra

Seite 103 - Chapter 5

4-16 Windows Setup Step 4: Start the ft series Setup Follow the steps below to perform ft series setup: IMPORTANT: If you skip the settings of Step

Seite 104 - NEC ESMPRO Agent

Windows Setup 4-17 6. “Important 1” message will appear. Read the message and follow the instructions. 7. “Important 2” message will ap

Seite 105 - • Empty capacity of hard

4-18 Windows Setup 9. Important 4” message will appear. Read the message and follow the instructions. 10. “Important 5” message wi

Seite 106

Windows Setup 4-19 CHECK: The message “The system will be rebooted.” appears on the screen momentarily. The server will restart automatically and no

Seite 107 - IMPORTANT:

4-20 Windows Setup The additional ft Update CD will be used. Are you sure [Y,N]? The additional ft Update CD will not be used. Are you sure [

Seite 108 - Installation

Windows Setup 4-21 IMPORTANT: When the usage of the “NEC Express5800/ft series ft Update CD” is not selected, the above message will not appear. Go

Seite 109

4-22 Windows Setup 22. The confirmation message for input size of the partition to install the OS will appear. When it is correct, enter

Seite 110

Windows Setup 4-23 26. When the completion of copying Microsoft HotFix, the following message will appear. Follow the instruction on the screen, i

Seite 111 - Setup of NEC ESMPRO Agent

4-24 Windows Setup 29. When copying is complete, the installation of Windows Server 2003 will be started automatically. IMPORTANT:

Seite 112

Windows Setup 4-25 NEC Express5800/ft series clear installation ** Please do not perform any operations. ** ** The system will restart automatica

Seite 113

i Preface Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in term

Seite 114 - NEC MWA

4-26 Windows Setup NEC Express5800/ft series clear installation ** Please do not perform any operations. ** ** The system will restart automati

Seite 115 - System Requirement

Windows Setup 4-27 37. The following screen will appear and the setup of Express Report Service will start. User intervention is not required. The E

Seite 116 - Setting up PCs on a Network

4-28 Windows Setup 39. After installation of Windows HotFix is complete, installation is continued. User intervention is not required. When the

Seite 117 -  Windows 95/98/Me:

Windows Setup 4-29 40. After restarting, the [Welcome to the Windows Setup Wizard] screen will appear. Click [Next>] and follow the instructio

Seite 118

4-30 Windows Setup 43. The following screen will appear. Follow the instruction in the screen and remove the CD from the drive, and then press any

Seite 119

Windows Setup 4-31 Step 5: Set Dual LAN Configuration The NEC Express5800/ft series builds a dual LAN configuration by using "Stratus emb-82559

Seite 120 - Chapter 6

4-32 Windows Setup [Team #1: Adaptive Fault Tolerance Mode] is added to Network Component Tree. 4. Select [Stratus emb-82559 10/100 Enet Ad

Seite 121 - System Repair

Windows Setup 4-33 7. Click [OK]. The [Intel(R)PROSet II] dialog box closes after a while, and the settings become effective. IMPORTANT:  The [Di

Seite 122

4-34 Windows Setup Step 6: Set Dual Disk Configuration NEC Express5800/ft series secures data by setting dual disk configuration using “Disk Manage

Seite 123 - Starting up Recovery Console

Windows Setup 4-35 4. Confirm that the hard disk to be converted is the hard disk where the system is installed and click [Convert]. If the sele

Seite 124

ii About This User’s Guide This User's Guide helps a user to properly setup and use the product. Consult this guide when you set up the product.

Seite 125

4-36 Windows Setup 6. If the inserted hard disk is not a dynamic disk, right-click the disk and perform “Convert to Dynamic Disk”. 7. Right-c

Seite 126

Windows Setup 4-37 9. Confirm that the mirroring of the HDD has been started in the disk manager. 10. When the “Resynching” shown in 9 changes to

Seite 127

4-38 Windows Setup Setting Dual Disk Configuration by the RDR (Rapid Disk Resync) function On a model supporting the RDR function, dual disk config

Seite 128 - Updating the System

Windows Setup 4-39 Registering RDR key When using the RDR function for the first time, follow the steps below to register the key: 1. Insert “RDR Ke

Seite 129

4-40 Windows Setup 3. When RDR is successfully configured, the following two pop-up messages appear. On the “Warning” pop-up, click [OK], and on

Seite 130

Windows Setup 4-41 6. Start “RDR Utility”, right-click the mounted disk and click [Add RDR Virtual Disk]. IMPORTANT: If the mounted disk has not

Seite 131

4-42 Windows Setup 7. Select [Logical Disk Information] then [RDR Virtual Disk] and confirm that the duplication process has been started. TI

Seite 132

Windows Setup 4-43 Step 7: Update Software Follow the instructions below and apply necessary update modules: <When the NEC Express5800/ft series

Seite 133

4-44 Windows Setup (After modification) Step 9: Create Volume With NEC Express5800/ft series, all volumes needs to be mirrored. For creati

Seite 134

Windows Setup 4-45 Step 10: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation, and it is automatically installed

Seite 135

iii Additional symbols The following symbols are used throughout this User's Guide in addition to the caution symbols described at the beginning.

Seite 136

4-46 Windows Setup < Setup of receiving SNMP packets from specific communities only > Change the name of the community receiving SNMP packets

Seite 137

Windows Setup 4-47 Step 11: Enable Boot Monitoring Function Enable the “Boot Monitoring” setting which has been disabled in “Step 3: Disable Boot Mon

Seite 138

4-48 Windows Setup Step 12: Set up Failure Management Make the following settings beforehand to ensure quick recovery from failure. Set Memory Dum

Seite 139 - Troubleshooting

Error! Style not defined. 4-49 4. Enter the location, where debug information is to be written, in the text box. When writing debug information unde

Seite 140 - Problems with Windows Setup

4-50 Windows Setup 5. Click [Settings] in the [Performance] box. The [Performance Options] window appears. 6. Click the [Advanced] tab on th

Seite 141

Error! Style not defined. 4-51 8. Change the value set for [Initial Size] in the [Paging file size for selected drive] box to the [Recommended] valu

Seite 142

4-52 Windows Setup Set Dr. Watson Dr. Watson of Windows Server 2003 is a debugger for application errors. When detecting an application error, Dr.

Seite 143 - Problems with System Repair

Error! Style not defined. 4-53 5. Select the following check boxes in the [Options] box.  [Dump Symbol Table]  [Dump All Thread Contexts]  [Appen

Seite 144

4-54 Windows Setup Install a Network Monitor A network monitor is useful for examining the causes of network failures and taking the countermeasure

Seite 145

Error! Style not defined. 4-55 Set MTBF Type In this section, you can specify operations to be performed when failures occur on CPU or PCI modules. N