Using RDR for Fault Tolerance
Disk Storage Management 4-7
To enable or disable read-load balancing globally
1. In ftSMC, expand ftServer Drivers, right-click SCSI Port Duplex
Driver - Sradisk_Driver, and select Properties.
2. On the dialog box, click the right-most Properties tab.
3. In the GlobalRdrPlexLoadBalancing field, select On or Off, and click OK.
NOTE
Global settings do not overwrite settings made on
individual RDR physical disks.
To add a physical disk to an RDR virtual disk
1. Insert and latch disks (see Figure 4-1) into corresponding slots in the enclosures.
(See “Finding a Physical Disk” on page 4-25 for an explanation of the numeric
values in the figures.)
In your Express5800/320Ma system, the internal storage disks are numbered 3-2-1
from top to bottom in a rack-mounted system. See Ta ble 4-1 and Figure 4-1.
Table 4-1. RDR Disk Numbering
ftSMC Console Pane
Node
ftSMC Details Pane
ObjectName Property Location in System
Storage Enclosure - 40
Slot-1, Disk-0 Harddisk0 Bottom disk drive
Slot-2, Disk-1 Harddisk1 Middle disk drive
Slot-3, Disk-2 Harddisk2 Top disk drive
Logical Disk Information
RDR Virtual Disk 1 Harddisk0 Bottom disk drive
RDR Virtual Disk 2 Harddisk1 Middle disk drive
RDR Virtual Disk 3 Harddisk2 Top disk drive