Sample Configuration
Sample Configuration 4-5
7. Check Scan Idle, if necessary, to enable specification of a Time between alerts
(in seconds) value. The default is 3600.
The Percent radio button is automatically selected, since disk free space is a
percentage of total disk space.
However, you can change the Units value to Megabytes if you want.
8. If you want to change the measured units from Percentage to Megabytes, check
the Megabytes radio button and click Yes to the dialog box that appears, as shown
in Figure 4-1.
Figure 4-1. Changing Units of Measurement
9. Specify values for:
Low Threshold Warning. The percentage of disk free space that would
initiate a warning (less severe than an alarm). The default is 30 percent.
Low Threshold Alarm. The percentage of disk free space that would initiate
an alarm. The default is 20 percent.
High Threshold Warning and High Threshold Alarm are grayed out for this
instance.
10. Put your changes into effect by following the procedure in Making Changes
Effective” on page 4-8.
Configuring Event Log Messages
To configure Event Log Messages
1. On the Express5800/320Ma Monitored Instances tab, select one of the event-log
instances:
Event Log: Application Error Messages.
Event Log: Application Warning Messages.
Event Log: System Error Messages.