8.7 System environment
♦Threshold for Temperature / Power Voltage / Fan Monitoring
The threshold for temperature/power voltage/fan cannot be displayed or changed. However, some models can only
display the threshold of the [Information of server state/constitution] of NEC ESMPRO Manager.
NEC ESMPRO Agent performs monitoring with the optimal threshold set on each model.
♦Display for Temperature / Power Voltage / Fan Sensors
On some models, temperature/power voltage/fan sensors do not have information on the status, current values,
revolutions, thresholds, etc. Note that the following may be displayed when referring to the applicable sensor on NEC
ESMPRO Manager.
- Display of the [Information of server state/constitution] of NEC ESMPRO Manager, the status is shown as
"Unknown" (grayed out).
- Display of the [Information of server state/constitution] of NEC ESMPRO Manager, the current value and
revolutions are not displayed, or they are shown as "Unknown".
Even if the above are displayed, there is no problem as the monitoring is being performed.
♦Case cover monitoring
The alert according to the opening and shutting of the case cover is not alerted of by the model that supports the case
cover monitoring in initialization either.
The alert of the opening and shutting of the case cover comes to be informed of by changing the setting with a set tool
of the alert report function (Alert manager).
The state of the server state color and the case cover is reflected by [Information of server state/constitution] of NEC
ESMPRO Manager regardless of the record setting.
♦Display of power supply
Tedium is correctly displayed though information on the power source module mounted with NEC ESMPRO Manager is
not displayed even if the power source module is mounted while starting when the device of the redundant power
supply composition is started by non-redundant power supply composition.
Restart OS to reflect the mounted state of the power supply module.
♦Display of the [Information of server state/constitution] of NEC ESMPRO Manager
when the redundant fan is removed/inserted
If the redundant fan is removed/inserted in hot-swap mode, the latest configuration information may not be displayed of
the [Information of server state/constitution] of NEC ESMPRO Manager.
The following event is logged when the redundant fan is removed/inserted. If the latest configuration information is not
displayed, restart the SNMP service.
Source : ESMCommonService
ID : 1602
Description : A new device is connected to the slot or the connector.
27