5-4 Procedures after Completion of Installation
# # # #
# Third, create a view for us to let the group have rights to:
# name incl/excl subtree mask(optional)
view all included .1 80
# # # #
# Finally, great the group read-only access to the systemview view.
# group context sec.model sec.level prefix read write notif
access notConfigGroup “” any noauth exact all all
none
3. Start setting of snmpd
Set snmpd to start automatically.
4. Start setting of portmap
Set portmap to start automatically.
5. Setting firewall
When monitoring from the NEC ESMPRO Manager, use the following port.
If you set the firewall on your environment, set the access permission to the following port.
snmp 161/udp
snmp-trap 162/udp
Installation procedure
TIPS: The NEC ESMPRO Agent is already installed to the hard disk drive of the server at
the time of shipment. Also, it is automatically installed when Linux for NEC
Express5800/ft series is installed.
1. Log in to the system as a root user.
2. Set the Back Up CD-ROM2 to the CD-ROM drive.
3. Enter the following command to mount the CD-ROM.
In this example, the mount point is assumed to be “mnt/cdrom”.
# mount /mnt/cdrom