ccs
[Overview]
Starts Consistency Check of Logical Drives in the RAID Controllers in which Patrol Read is disabled or not
supported.
[Format]
raidcmd ccs
[Description]
Starts Consistency Check of Logical Drives in the RAID Controllers in which Patrol Read is disabled or not
supported.
[Condition]
Allow to start Consistency Check to Logical Drive by ccs with the following situation.
- RAID Controller does not have the function of Patrol Read.
- Patrol Read is disabled.
- RAID Controller has the function of Consistency Check.
- The RAID Level of the Logical Drive is not 0.
- The status of the Logical Drive is [Online].
- It is not running Consistency Check to the Logical Drive now.