NEC Express5800/120Li Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach RAID-Kontroller NEC Express5800/120Li herunter. NEC Express5800/120Li User's Guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Power Console Plus™

NEC Express5800 series Power Console Plus™ User’s Guide ONL-4140bN-COMMON-119-99-0508

Seite 2 - Preface

– 7 – 6. Enter the password to permit full access to Power Console Plus, and click [Next]. Installation starts. When automatic setup completes, [Fini

Seite 3 - Contents

– 8 – 2.4 ENVIRONMENT SETUP Set up the environment as explained below. Setting HOSTS File Setting of HOSTS file is needed when control is performed v

Seite 4 - 1. Overview

– 9 – Modifying REGSERV.DAT File Modification of the management server information is necessary when control is performed via the network. Modify mana

Seite 5 - 1.2 COMPONENTS

– 10 – Change of the password permitting the full access To change the password specified at installation that permits the full access, use the passwo

Seite 6

– 11 – 2.5 UNINSTALLING POWER CONSOLE PLUS Take the following steps to uninstall Power Console Plus: 1. Power on the server and start Windows. 2. S

Seite 7 - 2. Server Setup

– 12 – 3. Management PC Setup This section explains Power Console Plus setup in a computer that manages servers via the network (TCP/IP). 3.1 OPERAT

Seite 8 - 2.2 PREPARATIONS

– 13 – 3.2 PREPARATIONS This section explains prerequisites for setup. TCP/IP setting for Windows must be completed. Updating of the system must be co

Seite 9 - 2.3 INSTALLATION

– 14 – 3.3 INSTALLATION Take the following steps to install Power Console Plus: 1. Power on the server to start Windows. 2. Set the provided CD-ROM

Seite 10

– 15 – 5. Specify the directory to install the Power Console Plus, and click [Next]. Installation starts. When automatic setup completes, [Finish to

Seite 11 - 2.4 ENVIRONMENT SETUP

– 16 – 3.4 ENVIRONMENT SETUP Set up the environment as explained below. Setting HOSTS File Set the server information, management server information,

Seite 12 - Modifying REGSERV.DAT File

Preface This manual explains "Power Console Plus" that is used with NEC Express5800 series connected with the LSI Logic disk array controlle

Seite 13

– 17 – Modifying REGSERV.DAT File Modify management server information registered in the REGSERV.DAT file that is provided/browsed by Power Console Pl

Seite 14

– 18 – 3.5 UNINSTALLING POWER CONSOLE PLUS Take the following steps to uninstall Power Console Plus: 1. Power on the server and start Windows. 2. S

Seite 15 - 3. Management PC Setup

– 19 – 4. Features of Power Console Plus This section explains the features of Power Console Plus. The screen as shown below appears when Power Conso

Seite 16 - 3.2 PREPARATIONS

– 20 – 4.1 TOOLBAR ICONS Power Console Plus includes several toolbar icons at the top of the screen. These icons provide easy access to Power Console

Seite 17 - 3.3 INSTALLATION

– 21 – Adapter Properties Icon Click on this icon to display the properties of the selected controller. Physical Drive Icon Click on this icon to d

Seite 18

– 22 – Logical Drive Icon Click on this icon to display the properties of the selected logical drive. Rebuild Rate Icon Click on this icon to chang

Seite 19 - 3.4 ENVIRONMENT SETUP

– 23 – Display Log Icon Click on this icon to display the log as shown below. NOTE: Power Console Plus logs all events to Raid.log. Raid.log is crea

Seite 20

– 24 – Help Icon Click on this icon to display information about Power Console Plus.

Seite 21

– 25 – 4.2 MENUBAR OPTIONS The Power Console Plus menus are: Option Description Configuration Choose this option to start the Power Console Plus Wiza

Seite 22 - Element Description

– 26 – Automatic Configuration: The Wizard examines the system (e.g., connected physical drives and check mark on Redundancy checkbox) and automatical

Seite 23 - 4.1 TOOLBAR ICONS

Contents 1. Overview ... 1 1.1 Majo

Seite 24 - Physical Drive Icon

– 27 – Custom Configuration: You can determine the configuration by specifying in detail the physical drives to be used and the logical drive to be cr

Seite 25 - Rescan Icon

– 28 – Display Choose this option to display the current RAID system configuration. Print Choose this option to print the current RAID system configur

Seite 26 - Exit Icon

– 29 – Adapter Menu The options on the Adapter menu are described below. Option Description Remarks Update Firmware – This option is not available

Seite 27 - Help Icon

– 30 – Option Description Remarks Alarm Control Choose this option to enable or disable the system alarm when the physical drive fails. Fast Initia

Seite 28 - 4.2 MENUBAR OPTIONS

– 31 – Properties Choose this option to display the controller properties. Rebuild Rate Choose Rebuild Rate to select the amount of system resources

Seite 29 - Automatic Configuration:

– 32 – View Log Select this option to display the MegaRAID event log. View NVRAM Event Log The log of NVRAM is displayed. View Bad Block Log The Ba

Seite 30

– 33 – Alarm Control The alarm generates a beeping sound when one or more physical disks fail. The sound continues until Silence Alarm is selected. Af

Seite 31

– 34 – Disable(Enable) Check Consistency Restoration It is set up whether the mismatching detected with the adjustment check is restored. Please do no

Seite 32 - Adapter Menu

– 35 – Physical Drive Menu Rebuild Choose the Rebuild option to rebuild one or more failed disk drives. Select [Abort Rebuild] to stop the rebuild pr

Seite 33 - Option Description Remarks

– 36 – Property Choose this option to display the properties of the selected physical drive. If you select [Processor] to display properties, the [

Seite 34

– 1 – 1. Overview 1.1 MAJOR FUNCTIONS Power Console Plus is a utility to RAID system Use of Power Console Plus enables operations (e.g., monitoring an

Seite 35 - Icon Description

– 37 – Logical Drv Menu Initialize Choose this option to initialize the selected logical drive or drives. You can view the progress of initialization

Seite 36 - Setting Description

– 38 – Properties Choose [Properties] to display the properties of the selected logical drive. Each logical drive can be displayed by selecting the [P

Seite 37

– 39 – You can choose Write Back or Write Thru. Write Policy Description Write Back The controller sends a data transfer completion signal to the ho

Seite 38 - Physical Drive Menu

– 40 – Progress Menu The features on this menu are available only when a rebuild, initialization, check consistency, or drive reconstruction are in pr

Seite 39

– 41 – 5. Running Power Console Plus This section describes how to run Power Console Plus. Described below is simple terminology and basic operations

Seite 40 - Logical Drv Menu

– 42 – Displaying Physical Drive Properties Double-click on the icon that represents the physical drive to display the properties of the selected phys

Seite 41 - Read Policy Description

– 43 – 5.1 CONFIGURING ARRAYS AND LOGICAL DRIVES This section describes how to configure arrays and logical drives. Step 1 Choose Wizard from the Con

Seite 42 - Write Policy Description

– 44 – Step 2 Select a physical drive in the Ready status. Click on [Add to Array] button to assign physical drives to the new array. Click on [Accept

Seite 43 - Progress Menu

– 45 – Setting Advanced Parameter Set each parameter on the screen. NOTE: Some parameter values may be restricted to ensure the system perform

Seite 44

– 46 – Step 5 Click on [OK] in the confirmation screen. The new configuration is saved in the controller. Step 6 Click on [OK] in the confirmation

Seite 45

– 2 – 1.2 COMPONENTS Power Console Plus consists of the following six components: SNMP Agent Install SNMP Agent in the NEC Express server in which the

Seite 46 - Type Description

– 47 – 5.2 REBUILDING PHYSICAL DRIVE This section describes how to rebuild the physical drive. Step 1 On [Physical Devices View] in the main menu, se

Seite 47

– 48 – 5.3 CHECK CONSISTENCY ON LOGICAL DRIVE This section describes how to perform consistency check on logical drive. Step 1 Select an icon of log

Seite 48 - Setting Advanced Parameter

– 49 – 5.4 ONLINE CAPACITY EXPANSION This section describes the procedures for online capacity expansion. Add Capacity You can add a physical drive t

Seite 49 - Changing Array Configuration

– 50 – Adding Capacity using Power Console Plus On the main Power Console Plus screen, verify that the drive(s) that are added display on the appropri

Seite 50 -  It is recommended to check

– 51 – The second method is: Step 1 On [Physical Devices View] of the main menu, select the physical drive(s) you want to add, and on [Logical Devices

Seite 51

– 52 – The third method is: Step 1 On [Physical Devices View] of the main menu, select the physical drive(s) icon you want to add, and drag it to the

Seite 52 - Add Capacity

– 53 – 6. Periodic Consistency Check Make a periodic consistency check on array disks and correct inconsistency detected. Doing so prevents a failure

Seite 53

– 54 – Argument Description arg1 -cons Sets a consistency check schedule. Other arg parameters are used to set time. If no other arg parameters a

Seite 54

– 55 – 7. Notes 1. The following event log is sometimes registered when uninstalling Power Console Plus. But there is no problem. Source: Service Con

Seite 55

– 3 – Power Console Plus components to be installed are different between the target servers and management PC. Server NEC Express server in which the

Seite 56 - Execute form

– 4 – 2. Server Setup This section explains how to setup the Power Console Plus in the NEC Express server configuring RAID system 2.1 OPERATING ENV

Seite 57 - Examples of use

– 5 – 2.2 PREPARATIONS This section explains prerequisites for setup. The driver for the RAID system must be installed. The SNMP service of Windows mu

Seite 58 - 7. Notes

– 6 – 2.3 INSTALLATION Take the following steps to install Power Console Plus: 1. Power on the server to start Windows 2000 / Windows 2003 Server. 2.

Kommentare zu diesen Handbüchern

Keine Kommentare